ChemSpider 2D Image | lindane | C6H6Cl6

lindane

  • Molecular FormulaC6H6Cl6
  • Average mass290.830 Da
  • Monoisotopic mass287.860077 Da
  • ChemSpider ID10481896
  • defined stereocentres - 6 of 6 defined stereocentres


More details:



Featured data source



Validated by Experts, Validated by Users, Non-Validated, Removed by Users

(1a,2a,3b,4a,5a,6b)-1,2,3,4,5,6-Hexachlorocyclohexane
(1R,2S,3r,4R,5S,6r)-1,2,3,4,5,6-Hexachlorcyclohexan [German] [ACD/IUPAC Name]
(1R,2S,3r,4R,5S,6r)-1,2,3,4,5,6-Hexachlorocyclohexane [ACD/IUPAC Name]
(1R,2S,3r,4R,5S,6r)-1,2,3,4,5,6-Hexachlorocyclohexane [French] [ACD/IUPAC Name]
1,2,3,4,5,6-Hexachlorocyclohexane g-Isomer
1a,2a,3b,4a,5a,6b-Hexachlorocyclohexane
1α,2α,3β,4α,5α,6β-Hexachlorocyclohexane
200-401-2 [EINECS]
More...

Validated by Experts, Validated by Users, Non-Validated, Removed by Users

ENT 7796 [DBID]
g-666 [DBID]
233390_ALDRICH [DBID]
442598_SUPELCO [DBID]
45548_RIEDEL [DBID]
49049_SUPELCO [DBID]
55963-79-6; 58-89-9 [DBID]
AI3-07796 [DBID]
BRN 1907337 [DBID]
BRN 1908224 [DBID]
More...
  • Experimental Physico-chemical Properties
  • Miscellaneous
    • Appearance:

      White to yellow, crystalline powder with a slight, musty odor. [pesticide] NIOSH GV4900000
    • Toxicity:

      Organic Compound; Organochloride; Pesticide; Insecticide; Pollutant; Drug; Synthetic Compound; Antiscabies Agent Toxin, Toxin-Target Database T3D0032
    • Safety:

      P03AB02 Wikidata Q282003
    • First-Aid:

      Eye: Irrigate immediately Skin: Soap wash promptly Breathing: Respiratory support Swallow: Medical attention immediately NIOSH GV4900000
    • Exposure Routes:

      inhalation, skin absorption, ingestion, skin and/or eye contact NIOSH GV4900000
    • Symptoms:

      Irritation eyes, skin, nose, throat; headache; nausea; clonic convulsions; respiratory difficulty; cyanosis; aplastic anemia; muscle spasm; in animals: liver, kidney damage NIOSH GV4900000
    • Target Organs:

      Eyes, skin, respiratory system, central nervous system, blood, liver, kidneys NIOSH GV4900000
    • Incompatibility:

      Corrosive to metals NIOSH GV4900000
    • Personal Protection:

      Skin: Prevent skin contact Eyes: No recommendation Wash skin: When contaminated Remove: When wet or contaminated Change: Daily Provide: Quick drench NIOSH GV4900000
    • Exposure Limits:

      NIOSH REL : TWA 0.5 mg/m 3 [skin] OSHA PEL : TWA 0.5 mg/m 3 [skin] NIOSH GV4900000
    • Bio Activity:

      Lindane(?-Hexachlorocyclohexane) is an organochlorine chemical variant of hexachlorocyclohexane that has been used both as an agricultural insecticide and as a pharmaceutical treatment for lice and scabies. MedChem Express HY-A0085
      Others MedChem Express HY-A0085
  • Gas Chromatography
    • Retention Index (Kovats):

      1703 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column type: Capillary; Start T: 160 C; CAS no: 58899; Active phase: OV-1; Data type: Kovats RI; Authors: Erdmann, F.; Rochholz, G.; Schutz, H., Retention-indices on OV-1 of approximately 170 commonly used pesticides, Mikrochim. Acta, 106, 1992, 219-226.) NIST Spectra nist ri
      1751 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column diameter: 0.22 mm; Column length: 25 m; Column type: Capillary; Start T: 200 C; CAS no: 58899; Active phase: BP-1; Carrier gas: N2; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Japp, M.; Gill, R.; Osselton, M.D., Comparison of drug retention indices determined on packed, wide bore capillary and narrow bore capillary columns, J. Forensic Sci., 32(6), 1987, 1574-1586.) NIST Spectra nist ri
      1756 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column diameter: 0.53 mm; Column length: 25 m; Column type: Capillary; Start T: 200 C; CAS no: 58899; Active phase: BP-1; Carrier gas: N2; Phase thickness: 1 um; Data type: Kovats RI; Authors: Japp, M.; Gill, R.; Osselton, M.D., Comparison of drug retention indices determined on packed, wide bore capillary and narrow bore capillary columns, J. Forensic Sci., 32(6), 1987, 1574-1586.) NIST Spectra nist ri
      1728 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 2 m; Column type: Packed; CAS no: 58899; Active phase: SE-30; Carrier gas: N2; Substrate: Chromosorb W HP; Data type: Kovats RI; Authors: Osselton, M.D.; Snelling, R.D., Chromatographic Identification of Pesticides, J. Chromatogr., 368, 1986, 265-271.) NIST Spectra nist ri
      1757 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 1.5 m; Column type: Packed; CAS no: 58899; Active phase: SE-30; Carrier gas: He; Substrate: Chromosorb G HP (80-100 mesh); Data type: Kovats RI; Authors: Ramsey, J.D.; Lee, T.D.; Osselton, M.D.; Moffat, A.C., Gas-liquid chromatographic retention indices of 296 non-drug substances on SE-30 or OV-1 likely to be encountered in toxicological analyses, J. Chromatogr., 184, 1980, 185-206.) NIST Spectra nist ri
      1735 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 2 m; Column type: Packed; Start T: 200 C; CAS no: 58899; Active phase: OV-1; Data type: Kovats RI; Authors: Dubsky, H.; Hana, K.; Komarkova, M.; Rittich, B., Stanoveni residui chlorovanych pesticidu plynovou chromatografii, Vet. Med. (Prague), 24(3), 1979, 493-498.) NIST Spectra nist ri
    • Retention Index (Lee):

      298 (Program type: Ramp; Column cl... (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 280 C; End time: 10 min; Start time: 5 min; CAS no: 58899; Active phase: HP5-MS; Carrier gas: Helium; Phase thickness: 0.25 um; Data type: Lee RI; Authors: Vrana, B.; Paschke, H.; Paschke, A.; Popp, P.; Schuurmann, G., Performance of semipermeable membrane devices for sampling of organic contaminants in groun water, J. Envirom. Monit., 7, 2005, 500-508.) NIST Spectra nist ri
    • Retention Index (Normal Alkane):

      1732 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.20 mm; Column length: 25 m; Column type: Capillary; Heat rate: 6 K/min; Start T: 60 C; End T: 240 C; CAS no: 58899; Active phase: OV-101; Carrier gas: Nitrogen; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Zenkevich, I.G.; Eliseenkov, E.V.; Kasatochkin, A.N., Chromatographic Identification of Cyclohexane Chlorination Products by an Additive Scheme for the Prediction of Retention Indices, Chromatographia, 70(5/6), 2009, 839-849.) NIST Spectra nist ri
      1744 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.20 mm; Column length: 25 m; Column type: Capillary; Heat rate: 6 K/min; Start T: 60 C; End T: 240 C; CAS no: 58899; Active phase: OV-101; Carrier gas: Nitrogen; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Zenkevich, I.G.; Eliseenkov, E.V.; Kasatochkin, A.N., Chromatographic Identification of Cyclohexane Chlorination Products by an Additive Scheme for the Prediction of Retention Indices, Chromatographia, 70(5/6), 2009, 839-849.) NIST Spectra nist ri
      1710.6 (Program type: Complex; Column... (show more) class: Standard non-polar; Column diameter: 0.25 mm; Column length: 60 m; Column type: Capillary; Description: 130C(21min) =>10C/min=> 200C (10min) =>1C/min =>232C (3min); CAS no: 58899; Active phase: HP-1; Carrier gas: N2; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Garrido Frenich, A.; Martinez Vidal, J.L.; Moreno Frias, M.; Olea-Serrano, F.; Olea, N.; Cuadros Rodriguez, L., Determination of organochlorine pesticides by GC-ECD and GC-MS-MS techniques including an evaluation of the uncertainty associated with the results, Chromatographia, 57(3/4), 2003, 213-220.) NIST Spectra nist ri
      1713.6 (Program type: Complex; Column... (show more) class: Standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 50C(1min) =>20C/min =>120C => 5C/min => 300C(10min); CAS no: 58899; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Shimadzu Corporation, Analysis of 124 pesticides with capillary GC-FTD and GC-ECD, 2003.) NIST Spectra nist ri
      1730.2 (Program type: Complex; Column... (show more) class: Standard non-polar; Column diameter: 0.25 mm; Column length: 50 m; Column type: Capillary; Description: 80C(1min)=> 10C/min =>150C=> 3C/min =>220C => 40C/min =>280C; CAS no: 58899; Active phase: CP Sil 5 CB; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Ma, X.; Li, C.; Tao, C.; Liu, W.; Zheng, S., Multi-residue determination of 41 insecticides in garlic by gas chromatography and ion trap mass spectrometry using the selective ion storage technique, Rapid Commun. Mass Spectrom., 15, 2001, 15-19.) NIST Spectra nist ri
      1758.7 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column diameter: 0.53 mm; Column length: 20 m; Column type: Capillary; CAS no: 58899; Active phase: DB-1; Carrier gas: H2; Phase thickness: 1.5 um; Data type: Normal alkane RI; Authors: Gilvydis, D.M.; Walters, S.M., Gas chromatographic determination of captan, folpet, and captafol residues in tomatoes, cucumbers, and apples using a wide-bore capillary column: Interlaboratory study, J. Ass. Offic. Anal. Chem, 74(5), 1991, 830-835., Program type: Ramp; Column cl... (show more) ass: Semi-standard non-polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Heat rate: 2.8 K/min; Start T: 140 C; End T: 270 C; End time: 1 min; Start time: 2 min; CAS no: 58899; Active phase: DB-5; Carrier gas: He; Phase thickness: 1.5 um; Data type: Normal alkane RI; Authors: Lopez-Avila, V.; Benedicto, J.; Baldin, E.; Beckert, W.F., Analysis of classes of compounds of environmental concern: III. Organochlorine pesticides, J. Hi. Res. Chromatogr., 15, 1992, 319-328.) NIST Spectra nist ri
      1735.6 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.2 mm; Column length: 12 m; Column type: Capillary; Heat rate: 18 K/min; Start T: 60 C; End T: 265 C; Start time: 1 min; CAS no: 58899; Active phase: HP-1; Carrier gas: He; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Liao, W.; Joe, T.; Cusick, W.G., Multiresidue screening method for fresh fruits and vegetables with gas chromatographic/mass spectrometric detection, J. Ass. Offic. Anal. Chem, 74(3), 1991, 554-565.) NIST Spectra nist ri
      1743.1 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 2 m; Column type: Packed; CAS no: 58899; Active phase: OV-101; Carrier gas: N2; Substrate: GAs Chrom Q (80-100 mesh); Data type: Normal alkane RI; Authors: Omura, M.; Hashimoto, K.; Ohta, K.; Iio, T.; Ueda, S.; Ando, K.; Fujiu, Y.; Hiraide, H., Effective application of the relative retention time diagram for gas chromatographic analysis of pesticides, J. Agric. Food Chem., 39(12), 1991, 2200-2205.) NIST Spectra nist ri
      1741.8 (Program type: Complex; Column... (show more) class: Standard non-polar; Column diameter: 0.2 mm; Column length: 25 m; Column type: Capillary; Description: 80 0C (0.5 min) ^ 25 0C/min -> 185 0C ^ 5 0C/min -> 225 0C (3 min); CAS no: 58899; Active phase: Methyl Silicone; Carrier gas: He; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Szeto, S.Y.; Price, P.M., Persistence of pesticide residues in mineral and organic soils in the Fraser Valley of British Columbia, J. Agric. Food Chem., 39(9), 1991, 1679-1684.) NIST Spectra nist ri
      1742.2 (Program type: Complex; Column... (show more) class: Standard non-polar; Column diameter: 0.2 mm; Column length: 25 m; Column type: Capillary; Description: 1 min at 100 0C; 100 - 150 0C at 30 deg/min; 2 min at 150 0C; 150 - 205 0C at 3 deg/min; 205 - 240 0C at 10 deg/min; 240 - 260 0C at 2 deg/min; 1 min at 260 0C; CAS no: 58899; Active phase: HP-1; Carrier gas: He; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Stan, H.-J., Application of Capillary Gas Chromatography with Mass Selective Detection to Pesticide Residue Analysis, J. Chromatogr., 467, 1989, 85-98.) NIST Spectra nist ri
      1713.8 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 1.1 m; Column type: Packed; Heat rate: 8.5 K/min; Start T: 50 C; End T: 300 C; CAS no: 58899; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb W HP; Data type: Normal alkane RI; Authors: Saxton, W.L., Emergence temperature indices and relative retention times of pesticides and industrial chemicals determined by linear programmed temperature gas chromatography, J. Chromatogr., 393, 1987, 175-194.) NIST Spectra nist ri
      1726.1 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 1.1 m; Column type: Packed; Heat rate: 8.5 K/min; Start T: 50 C; End T: 300 C; CAS no: 58899; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb W HP; Data type: Normal alkane RI; Authors: Saxton, W.L., Emergence temperature indices and relative retention times of pesticides and industrial chemicals determined by linear programmed temperature gas chromatography, J. Chromatogr., 393, 1987, 175-194.) NIST Spectra nist ri
      1715.1 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 1.8 m; Column type: Packed; CAS no: 58899; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb W HP; Data type: Normal alkane RI; Authors: Yurawecz, M.P.; Puma, B.J., Gas chromatographic determination of electron capture sensitive volatile industrial chemical residues in foods, using AOAC pesticide multiresidue extraction and cleanup procedures, J. Ass. Offic. Anal. Chem, 69(1), 1986, 80-86.) NIST Spectra nist ri
      1718.5 (Program type: Complex; Column... (show more) class: Standard non-polar; Column diameter: 0.247 mm; Column length: 15 m; Column type: Capillary; Description: 1 min at 90 C; 90-150 C at 20 deg/min; 150-250 C at 5 deg/min; hold at 250 C for elution of last component; CAS no: 58899; Active phase: SE-30; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Ripley, B.D.; Braun, H.E., Retention time data for organochlorine, organophosphorus, and organonitrogen pesticides on SE-30 capillary column and application of capillary gas chromatography to pesticide residue analysis, J. Ass. Offic. Anal. Chem, 66(5), 1983, 1084-1095.) NIST Spectra nist ri
      1720 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 2 m; Column type: Packed; Heat rate: 2.5 K/min; Start T: 120 C; End T: 200 C; CAS no: 58899; Active phase: SE-30; Substrate: Gas Chrom P; Data type: Normal alkane RI; Authors: Marozzi, E.; Gambaro, V.; Saligari, E.; Mariani, R.; Lodi, F., Use of the retention index in gas chromatographic studies of drugs, J. Anal. Toxicol., 6, 1982, 185-192.) NIST Spectra nist ri
      1775 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 50 0C(1 min) ^ 25 0C/min -> 125 0C ^ 10 0C/min -> 300 0C (10 min); CAS no: 58899; Active phase: 5 % Phenyl methyl siloxane; Carrier gas: Helium; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Department of Food Safety, Ministry of Health; Welfare, Analytical methods for residual compositional substances of agricultural chemicals, feed aadditives, and veterinary drugs in foods, 2006., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 2 m; Column type: Packed; Heat rate: 2.5 K/min; Start T: 120 C; End T: 200 C; CAS no: 58899; Active phase: OV-1; Substrate: Gas Chrom P; Data type: Normal alkane RI; Authors: Marozzi, E.; Gambaro, V.; Saligari, E.; Mariani, R.; Lodi, F., Use of the retention index in gas chromatographic studies of drugs, J. Anal. Toxicol., 6, 1982, 185-192.) NIST Spectra nist ri
      1745 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Other; CAS no: 58899; Active phase: Methyl Silicone; Data type: Normal alkane RI; Authors: Ardrey, R.E.; Moffat, A.C., Gas-liquid chromatographic retention indices of 1318 substances of toxicological interest on SE-30 or OV-1 stationary phase, J. Chromatogr., 220, 1981, 195-252.) NIST Spectra nist ri
      1715 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Other; CAS no: 58899; Active phase: Methyl Silicone; Data type: Normal alkane RI; Authors: Ardrey, R.E.; Moffat, A.C., Gas-liquid chromatographic retention indices of 1318 substances of toxicological interest on SE-30 or OV-1 stationary phase, J. Chromatogr., 220, 1981, 195-252.) NIST Spectra nist ri
      1779 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 50 0C(1 min) ^ 25 0C/min -> 125 0C ^ 10 0C/min -> 300 0C (10 min); CAS no: 58899; Active phase: 5 % Phenyl methyl siloxane; Carrier gas: Helium; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Department of Food Safety, Ministry of Health; Welfare, Analytical methods for residual compositional substances of agricultural chemicals, feed aadditives, and veterinary drugs in foods, 2006.) NIST Spectra nist ri
      1748.1 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 80C(1min) => 10C/min =>160C (5min) => 3C/min =>240C =>25C/min =>280C(10min); CAS no: 58899; Active phase: DB-5MS; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Chu, X.-G.; Hu, X.-Z.; Yao, H.-Y., Determination of 266 pesticide residues in apple juice by matrix solid-phase dispersion and gas chromatography-mass selective detection, J. Chromatogr. A, 1063, 2005, 201-210.) NIST Spectra nist ri
      1732.4 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 70C(2min) =>25C/min=>150C=> 3C/min =>200C =>8C/min=> 280C(10min); CAS no: 58899; Active phase: ZB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Albero, B.; Sanchez-Brunete, C.; Tadeo, J.L., Analysis of pesticides in honey by solid-phase extraction and gas chromatography-mass spectrometry, J. Agric. Food Chem., 52, 2004, 5828-5835.) NIST Spectra nist ri
      1775.2 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 80C(2min) =>15C/min =>190C(4min) => 10C/min => 290C(6min); CAS no: 58899; Active phase: CP-Sil 8CB-MS; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Goncalves, C.; Alpendurada, M.F., Solid-phase micro-extraction-gas chromatography-(tandem) mass spectrometry as a tool for pesticide residue analysis in water samples at high sensitivity and selectivity with confirmation capabilities, J. Chromatogr. A, 1026, 2004, 239-250.) NIST Spectra nist ri
      1768.6 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 70C(2min)=> 25C/min =>150C=> 3C/min =>200C =>8C/min=>280C(10min); CAS no: 58899; Active phase: ZB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Sanchez-Brunete, C.; Albero, B.; Tadeo, J.L., Multiresidue determination of pesticides in soil by gas chromatography-mass spectrometry detection, J. Agric. Food Chem., 52, 2004, 1445-1451.) NIST Spectra nist ri
      1744.9 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 70C(2min) =>25C/min =>150C=>3C/min => 200C=> 8C/min =>280C(10min); CAS no: 58899; Active phase: HP-5MS; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Wong, J.W.; Webster, M.G.; Bezabeh, D.Z.; Hengel, M.J.; Ngim, K.K.; Krynitsky, A.J.; Ebeler, S.E., Multiresidue determination of pesticides in malt beverages by capillary gas chromatography with mass spectrometry and selected ion monitoring, J. Agric. Food Chem., 52, 2004, 6361-6372.) NIST Spectra nist ri
      1740.9 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 80C(2.5min) =>50c/min=> 140C =>5C/min =>260C (3min); CAS no: 58899; Active phase: DB-5MS; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Garrido Frenich, A.; Martinez Vidal, J.L.; Moreno Frias, M.; Olea-Serrano, F.; Olea, N.; Cuadros Rodriguez, L., Determination of organochlorine pesticides by GC-ECD and GC-MS-MS techniques including an evaluation of the uncertainty associated with the results, Chromatographia, 57(3/4), 2003, 213-220.) NIST Spectra nist ri
      1752.7 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 57C(2min) => 40C/min=> 130C=> 5C/min=> 200C=> 7C/min=> 270C(10min); CAS no: 58899; Active phase: HP-5; Carrier gas: He; Phase thickness: 0.2 um; Data type: Normal alkane RI; Authors: Haib, J.; Hofer, I.; Renaud, J.-M., Analysis of multiple pesticide residues in tobacco using pressurized liquid extraction, automated solid-phase extraction clean-up and gas chromatography-tandem mass spectrometry, J. Chromatogr. A, 1020, 2003, 173-187.) NIST Spectra nist ri
      1760.7 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 70C(3.5min)=>25C/min =>180C(10min) =>10C/min =>300C; CAS no: 58899; Active phase: CP Sil 8 CB; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Prados-Rosales, R.C.; Luque Garcia, J.L.; Luque de Castro, M.D., Rapid analytical method for the determination of pesticide residues in sunflower seeds based on focused microwave-assisted Soxhlet extraction prior to gas chromatography-tandem mass spectrometry, J. Chromatogr. A, 993, 2003, 121-129.) NIST Spectra nist ri
      1772.1 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 70 0C (2 min) ^ 25 0C/min -> 150 0C ^ 3 0C/min -> 200 0C ^ 8 0C/min -> 280 0C (3 min); CAS no: 58899; Active phase: HP-5MS; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Richter, P.; Sepulveda, B.; Oliva, R.; Calderon, K.; Seguel, R., Screening and determination of pesticides in soil using continuous subcritical water extraction and gas chromatography-mass spectrometry, J. Chromatogr. A, 994, 2003, 169-177.) NIST Spectra nist ri
      1752.2 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 50C(1min) =>20C/min =>120C => 5C/min => 300C(10min); CAS no: 58899; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Shimadzu Corporation, Analysis of 124 pesticides with capillary GC-FTD and GC-ECD, 2003.) NIST Spectra nist ri
      1755 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 80 C (1 min) ^ 30 C/min -> 180 C (3 min) ^ 3 C/min -> 270 C; CAS no: 58899; Active phase: HP-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Concha-Grana, E.; Turnes-Carou, M.I.; Muniategui-Lorenzo, S.; Lopez-Mahia, P.; Fernandez-Fernandez, E.; Prada-Rodriguez, D., Optimisation of a programmed split-splitless injector in the gas chromatographic-mass spectrometric determination of organochlorine pesticides, J. Chromatogr. A, 958, 2002, 17-24.) NIST Spectra nist ri
      1783.9 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 50 C (1.5 min) ^ 30 C/min -> 180 C ^ 10 C/min -> 275 C (15 min); CAS no: 58899; Active phase: RTX-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Dabrowski, L.; Giergielewicz-Mozajska, H.; Biziuk, M.; Gaca, J.; Namiesnik, J., Some aspects of the analysis of environmental pollutants in sediments using pressurized liquid extraction and gas chromatography-mass spectrometry, J. Chromatogr. A, 957, 2002, 59-67.) NIST Spectra nist ri
      1768.2 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 70 C (3.5 min) ^ 50 C/min -> 150 C ^ 5 C/min -> 180 C (5 min) ^ 4 C/min -> 205 C (5 min) ^ 4 C/min -> 300 C (5 min); CAS no: 58899; Active phase: DB-5MS; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Martinez Vidal, J.L.; Arrebola, F.J.; Mateu-Sanchez, M., Application of gas chromatography-tandem mass spectrometry to the analysis of pesticides in fruits and vegetables, J. Chromatogr. A, 959, 2002, 203-213.) NIST Spectra nist ri
      1742.7 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 60 m; Column type: Capillary; Description: 60 0C ^ 8 0C/min -> 120 0C ^ 5 0C/min -> 260 0C ^ 10 0C -> 280 0C (10 min); CAS no: 58899; Active phase: DB-5; Carrier gas: H2; Data type: Normal alkane RI; Authors: Xue, X.Y.; Zhang, Q.; Liang, X.M.; Oxynos, K.; Kettrup, A.; Lu, P.C., Computer-assisted automatic peak recognition and result evaluation for analysis of chlorinated hydrocarbons in environmental samples, J. Chromatogr. A, 957, 2002, 37-44.) NIST Spectra nist ri
      1755.5 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 40C(2min) =>3C/min =>175C (4min) => 3C/min => 240C => 7C/min=>320C(10min); CAS no: 58899; Active phase: HP-5MS; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Lacorte, S.; Guiffard, I.; Fraisse, D.; Barcelo, D., Broad spectrum analysis of 109 priority compounds listed in the 76/464/CEE council directive using solid-phase extraction and GC/EI/MS, Anal. Chem., 72, 2000, 1430-1440.) NIST Spectra nist ri
      1788 (Program type: Ramp; Column cl... (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 30 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 50 C; End T: 300 C; End time: 4 min; Start time: 1 min; CAS no: 58899; Active phase: HP-5; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Murayama, H.; Mukai, H.; Mitobe, H.; Moriyama, N., Simple method for determining trace pesticides in air using extraction disks, Anal. Sci., 16, 2000, 257-263.) NIST Spectra nist ri
      1745.8 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.2 mm; Column length: 25 m; Column type: Capillary; Description: 100C(1min) => 30C/min=> 150C(2min) => 3C/min=> 205C => 10C/min =>260C(29min); CAS no: 58899; Active phase: SE-54; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Stan, H.-J., Pesticide residue analysis in foodstuffs applying capillary gas chromatography with mass spectrometric detection State-of-the-art use of modified DFG-multimethod S19 and automated data evaluation, J. Chromatogr. A, 892, 2000, 347-377.) NIST Spectra nist ri
      1757.7 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 50 C (1.13 min) ^ 30 C/min -> 150 C ^ 3 C/min -> 205 C ^ 10 C/min -> 250 C (20 min); CAS no: 58899; Active phase: HP-5; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Cook, J.; Engel, M.; Wylie, P.; Quimby, B., Multiresidue screening of pesticides in foods using retention time locking, GC-AED, database search, and GC/MS identification, J. AOAC Int., 82(2), 1999, 313-326.) NIST Spectra nist ri
      1748.5 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 45 m; Column type: Capillary; Description: 80 0C (3 min) ^ 20 0C/min -> 170 0C (7.5 min) ^ 3 0C/min -> 300 0C (7 min); CAS no: 58899; Active phase: Ultra-2; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Looser, R.; Ballschmiter, K., Gas chromatographic separation of semivolatile organohalogen compounds on the new stationary phase Optima.delta.-3, J. Chromatogr. A, 836, 1999, 271-284.) NIST Spectra nist ri
      1767.3 (Program type: Ramp; Column cl... (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 6 K/min; Start T: 60 C; End T: 260 C; End time: 12 min; CAS no: 58899; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Mogadati, P.; Louis, J.B.; Rosen, J.D., Multiresidue determination of pesticides in high-organic-content soils by solid-phase extraction and gas chromatography/mass spectrometry, J. AOAC Int., 82(3), 1999, 705-715.) NIST Spectra nist ri
      1754 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 60 m; Column type: Capillary; Description: 90 0C (4 min) ^ 18 0C/min -> 180 0C (1 min) ^ 0.9 0C/min -> 200 0C (1 min) ^ 1.5 0C/min -> 270 0C (15 min); CAS no: 58899; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Najam, A.R.; Korver, M.P.; Williams, C.C.; Burse, V.W.; Needham, L.L., Analysis of a mixture of polychlorinated biphenyls and chlorinated pesticides in human serum by column fractionation and dual-column capillary gas chromatography with electron capture detection, J. AOAC Int., 82(1), 1999, 177-185.) NIST Spectra nist ri
      1759.3 (Program type: Ramp; Column cl... (show more) ass: Semi-standard non-polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Heat rate: 4 K/min; Start T: 100 C; End T: 275 C; End time: 2 min; Start time: 5 min; CAS no: 58899; Active phase: RTX-5; Carrier gas: He; Phase thickness: 0.5 um; Data type: Normal alkane RI; Authors: Restek, Restek International, 1999 Product Guide, 1(1), 1999, 578-591, In original 578-591.) NIST Spectra nist ri
      1753.3 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 2.5 mm; Column length: 30 m; Column type: Capillary; Description: 60 0C (1 min) ^ 15 0C/min -> 180 0C (4 min) ^ 5 0C/min -> 205 0C ^ 20 0C/min -> 295 0C (5 min); overall run time is 27.5 min; CAS no: 58899; Active phase: HP-5; Carrier gas: He; Phase thickness: 2.5 um; Data type: Normal alkane RI; Authors: Johnson, P.D.; Rimmer, D.A.; Brown, R.H., Adaptation and application of a multi-residue method for the determination of a range of pesticides, including phenoxy acid herbicides in vegetation, ased on high-resolution gel permeation chromatographic clean-up and gas chromatographic analysis with mass-selective detection, J. Chromatogr. A, 765, 1997, 3-11.) NIST Spectra nist ri
      1756.9 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.2 mm; Column length: 29 m; Column type: Capillary; Description: 80 C (1 min) ^ 6 C/min -> 200 C (3 min) ^ 6 C/min -> 260 C (8 min); CAS no: 58899; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Papadopoulou-Mourkidou, E.; Patsias, J.; Kotopoulou, A., Determination of pesticides in soils by gas chromatography-ion trap mass spectrometry, J. AOAC Int., 80(2), 1997, 447-454.) NIST Spectra nist ri
      1740.1 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 80(1)-6^ ->200(3)-6^ -> 260(10); CAS no: 58899; Active phase: HP-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Patsias, J.; Papadopoulou-Mourkidou, E., Rapid method for the analysis of a variety of chemical classes of pesticides in surface and ground waters by off-line solid phase extraction and gas chromatography-ion trap mass spectrometry, J. Chromatogr. A, 740, 1996, 83-98.) NIST Spectra nist ri
      1747.4 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.2 mm; Column length: 25 m; Column type: Capillary; Description: 85 0C (1 min) ^ 40 0C/min -> 150 0C (2 min) ^ 10 0C/min -> 280 0C (20 min); CAS no: 58899; Active phase: HP-5; Carrier gas: He; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Holland, P.T.; McNaughton, D.E.; Malcolm, C.P., Multiresidue analysis of pesticides in wines by solid-phase extraction, J. AOAC Int., 77(1), 1994, 79-86.) NIST Spectra nist ri
      1751.1 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.20 mm; Column length: 25 m; Column type: Capillary; Description: 90 0C (1 min) ^ 30 0C/min -> 180 0C ^ 4 0C/min -> 270 0C (15 min); CAS no: 58899; Active phase: Ultra-2; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Hernandez, F.; Morell, I.; Beltran, J.; Lopez, F.J., Multi-residue procedure for the analysis of pesticides in groundwater: Application to samples from the Comunidad Valenciana, Spain, Chromatographia, 37(5/6), 1993, 303-312.) NIST Spectra nist ri
      1751.3 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.2 mm; Column length: 25 m; Column type: Capillary; Description: 1 min at 100 0C; 100-150 0C at 30 deg/min; hold at 150 0C for 1 min; 150 - 205 0C at 3 deg/min; 205 - 260 0C at 10 deg/min; 23 min at 260 0C; CAS no: 58899; Active phase: HP-5; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Stan, H.-J.; Heberer, Th., Automated recognition of target compounds at low levels in environmental samples by means of capillary gas chromatography-mass spectrometry with dedicated mass spectral libraries and the macro program AUTARG. II. Application to pesticides in the groundwater samples, J. Chromatogr., 653, 1993, 55-62.) NIST Spectra nist ri
      1750.3 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 57 0C (1 min) ^ 15 0C/min -> 130 0C (1 min) ^ 2.3 0C/min -> 270 0C (20 min); CAS no: 58899; Active phase: DB-5; Data type: Normal alkane RI; Authors: Bernal, J.L.; del Nozal, M.J.; Atienza, J.; Jimenez, J.J., Multidetermination of PCBs and pesticides by use of a dual GC column-dual detector system, Chromatographia, 33(1/2), 1992, 67-76.) NIST Spectra nist ri
      1748.7 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column type: Capillary; Description: 110 0C (1 min) ^ 15 0C/min -> 190 0C ^ 3 0C/min -> 270 0C (50 min); CAS no: 58899; Active phase: DB-5; Data type: Normal alkane RI; Authors: Hopper, M.L., Analysis of organochlorine presticide residues using simultaneous injection of two capillary columns with electron capture and electrolytic conductivity detectors, J. Ass. Offic. Anal. Chem, 74(6), 1991, 974-981.) NIST Spectra nist ri
      1749.7 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Description: 80 0C (2 min) ^ 20 0C/min -> 220 0C 91 min) ^ 5 0C/min -> 280 0C (6 min); CAS no: 58899; Active phase: DB-5; Carrier gas: He; Data type: Normal alkane RI; Authors: LeBel, G.L.; Williams, D.T., Determination of halogenated contaminants in human adipose tissue, J. Ass. Offic. Anal. Chem, 69(3), 1986, 451-458.) NIST Spectra nist ri
    • Retention Index (Linear):

      1709 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 25 m; Column type: Capillary; Heat rate: 1 K/min; Start T: 160 C; End T: 240 C; Start time: 1 min; CAS no: 58899; Active phase: OV-1; Phase thickness: 0.10 um; Data type: Linear RI; Authors: de Paoli, M.; Taccheo-Barbina, M.; Bontempelli, G., Gas chromatographic system for the identification of halogenated pesticides by retention indices using n-alkanes as standards, J. Chromatogr., 547, 1991, 355-365., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 25 m; Column type: Capillary; Heat rate: 1.5 K/min; Start T: 160 C; End T: 240 C; Start time: 1 min; CAS no: 58899; Active phase: OV-1; Phase thickness: 0.10 um; Data type: Linear RI; Authors: de Paoli, M.; Taccheo-Barbina, M.; Bontempelli, G., Gas chromatographic system for the identification of halogenated pesticides by retention indices using n-alkanes as standards, J. Chromatogr., 547, 1991, 355-365.) NIST Spectra nist ri
      1711 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 25 m; Column type: Capillary; Heat rate: 1 K/min; Start T: 160 C; End T: 240 C; Start time: 1 min; CAS no: 58899; Active phase: OV-1; Phase thickness: 0.10 um; Data type: Linear RI; Authors: de Paoli, M.; Taccheo-Barbina, M.; Bontempelli, G., Gas chromatographic system for the identification of halogenated pesticides by retention indices using n-alkanes as standards, J. Chromatogr., 547, 1991, 355-365., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 25 m; Column type: Capillary; Heat rate: 1.3 K/min; Start T: 160 C; End T: 240 C; Start time: 1 min; CAS no: 58899; Active phase: OV-1; Phase thickness: 0.10 um; Data type: Linear RI; Authors: de Paoli, M.; Taccheo-Barbina, M.; Bontempelli, G., Gas chromatographic system for the identification of halogenated pesticides by retention indices using n-alkanes as standards, J. Chromatogr., 547, 1991, 355-365., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 25 m; Column type: Capillary; Heat rate: 1.5 K/min; Start T: 160 C; End T: 240 C; Start time: 1 min; CAS no: 58899; Active phase: OV-1; Phase thickness: 0.10 um; Data type: Linear RI; Authors: de Paoli, M.; Taccheo-Barbina, M.; Bontempelli, G., Gas chromatographic system for the identification of halogenated pesticides by retention indices using n-alkanes as standards, J. Chromatogr., 547, 1991, 355-365., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 25 m; Column type: Capillary; Heat rate: 2 K/min; Start T: 160 C; End T: 240 C; Start time: 1 min; CAS no: 58899; Active phase: OV-1; Phase thickness: 0.10 um; Data type: Linear RI; Authors: de Paoli, M.; Taccheo-Barbina, M.; Bontempelli, G., Gas chromatographic system for the identification of halogenated pesticides by retention indices using n-alkanes as standards, J. Chromatogr., 547, 1991, 355-365.) NIST Spectra nist ri
      1713 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 25 m; Column type: Capillary; Heat rate: 1.3 K/min; Start T: 160 C; End T: 240 C; Start time: 1 min; CAS no: 58899; Active phase: OV-1; Phase thickness: 0.10 um; Data type: Linear RI; Authors: de Paoli, M.; Taccheo-Barbina, M.; Bontempelli, G., Gas chromatographic system for the identification of halogenated pesticides by retention indices using n-alkanes as standards, J. Chromatogr., 547, 1991, 355-365., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 25 m; Column type: Capillary; Heat rate: 2 K/min; Start T: 160 C; End T: 240 C; Start time: 1 min; CAS no: 58899; Active phase: OV-1; Phase thickness: 0.10 um; Data type: Linear RI; Authors: de Paoli, M.; Taccheo-Barbina, M.; Bontempelli, G., Gas chromatographic system for the identification of halogenated pesticides by retention indices using n-alkanes as standards, J. Chromatogr., 547, 1991, 355-365.) NIST Spectra nist ri
      1722.59 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Capillary; Heat rate: 4 K/min; Start T: 170 C; CAS no: 58899; Active phase: SP-2100; Carrier gas: H2; Data type: Linear RI; Authors: Podmaniczky, L.; Szepesy, L.; Lakszner, K.; Schomburg, G., Determination of Retention Indices in LPTGC, Chromatographia, 21(7), 1986, 387-391.) NIST Spectra nist ri
      1724.2 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Capillary; Heat rate: 2 K/min; Start T: 170 C; CAS no: 58899; Active phase: SP-2100; Carrier gas: H2; Data type: Linear RI; Authors: Podmaniczky, L.; Szepesy, L.; Lakszner, K.; Schomburg, G., Determination of Retention Indices in LPTGC, Chromatographia, 21(7), 1986, 387-391.) NIST Spectra nist ri
      1728.47 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Capillary; Heat rate: 6 K/min; Start T: 170 C; CAS no: 58899; Active phase: SP-2100; Carrier gas: H2; Data type: Linear RI; Authors: Podmaniczky, L.; Szepesy, L.; Lakszner, K.; Schomburg, G., Determination of Retention Indices in LPTGC, Chromatographia, 21(7), 1986, 387-391.) NIST Spectra nist ri
      1733.9 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Capillary; Heat rate: 2 K/min; Start T: 170 C; CAS no: 58899; Active phase: SP-2100; Carrier gas: H2; Data type: Linear RI; Authors: Podmaniczky, L.; Szepesy, L.; Lakszner, K.; Schomburg, G., Determination of Retention Indices in LPTGC, Chromatographia, 21(7), 1986, 387-391.) NIST Spectra nist ri
      1735.15 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Capillary; Heat rate: 4 K/min; Start T: 170 C; CAS no: 58899; Active phase: SP-2100; Carrier gas: H2; Data type: Linear RI; Authors: Podmaniczky, L.; Szepesy, L.; Lakszner, K.; Schomburg, G., Determination of Retention Indices in LPTGC, Chromatographia, 21(7), 1986, 387-391.) NIST Spectra nist ri
      1735.83 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Capillary; Heat rate: 4 K/min; Start T: 170 C; CAS no: 58899; Active phase: CP Sil 5 CB; Carrier gas: H2; Data type: Linear RI; Authors: Podmaniczky, L.; Szepesy, L.; Lakszner, K.; Schomburg, G., Determination of Retention Indices in LPTGC, Chromatographia, 21(7), 1986, 387-391.) NIST Spectra nist ri
      1737.79 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Capillary; Heat rate: 6 K/min; Start T: 170 C; CAS no: 58899; Active phase: SP-2100; Carrier gas: H2; Data type: Linear RI; Authors: Podmaniczky, L.; Szepesy, L.; Lakszner, K.; Schomburg, G., Determination of Retention Indices in LPTGC, Chromatographia, 21(7), 1986, 387-391.) NIST Spectra nist ri

Predicted data is generated using the ACD/Labs Percepta Platform - PhysChem Module, version: 14.00

Density: 1.6±0.1 g/cm3
Boiling Point: 288.0±0.0 °C at 760 mmHg
Vapour Pressure: 0.0±0.5 mmHg at 25°C
Enthalpy of Vaporization: 50.6±3.0 kJ/mol
Flash Point: 157.5±23.9 °C
Index of Refraction: 1.533
Molar Refractivity: 56.6±0.4 cm3
#H bond acceptors: 0
#H bond donors: 0
#Freely Rotating Bonds: 0
#Rule of 5 Violations: 0
ACD/LogP: 3.99
ACD/LogD (pH 5.5): 3.82
ACD/BCF (pH 5.5): 472.80
ACD/KOC (pH 5.5): 2858.51
ACD/LogD (pH 7.4): 3.82
ACD/BCF (pH 7.4): 472.80
ACD/KOC (pH 7.4): 2858.51
Polar Surface Area: 0 Å2
Polarizability: 22.5±0.5 10-24cm3
Surface Tension: 41.0±5.0 dyne/cm
Molar Volume: 182.6±5.0 cm3

Predicted data is generated using the US Environmental Protection Agency�s EPISuite™

                        
 Log Octanol-Water Partition Coef (SRC):
    Log Kow (KOWWIN v1.67 estimate) =  4.26
    Log Kow (Exper. database match) =  3.72
       Exper. Ref:  Hansch,C et al. (1995)
    Log Kow (Exper. database match) =  3.80
       Exper. Ref:  Hansch,C et al. (1995)
    Log Kow (Exper. database match) =  3.78
       Exper. Ref:  Hansch,C et al. (1995)
    Log Kow (Exper. database match) =  4.14
       Exper. Ref:  Hansch,C et al. (1995)

 Boiling Pt, Melting Pt, Vapor Pressure Estimations (MPBPWIN v1.42):
    Boiling Pt (deg C):  304.35  (Adapted Stein & Brown method)
    Melting Pt (deg C):  56.98  (Mean or Weighted MP)
    VP(mm Hg,25 deg C):  0.000506  (Modified Grain method)
    MP  (exp database):  112.5 deg C
    BP  (exp database):  60 @ 0.34 mm Hg deg C
    VP  (exp database):  3.52E-05 mm Hg at 25 deg C
    Subcooled liquid VP: 0.000258 mm Hg (25 deg C, exp database VP )

 Water Solubility Estimate from Log Kow (WSKOW v1.41):
    Water Solubility at 25 deg C (mg/L):  4.044
       log Kow used: 4.14 (expkow database)
       no-melting pt equation used
     Water Sol (Exper. database match) =  7.3 mg/L (25 deg C)
        Exper. Ref:  RICHARDSON,LT & MILLER,DM (1960)
     Water Sol (Exper. database match) =  2 mg/L (25 deg C)
        Exper. Ref:  WEIL,L ET AL. (1974)
     Water Sol (Exper. database match) =  0.24 mg/L (25 deg C)
        Exper. Ref:  WEIL,L ET AL. (1974)
     Water Sol (Exper. database match) =  10 mg/L (20 deg C)
        Exper. Ref:  SHIU,WY ET AL (1990)
     Water Sol (Exper. database match) =  8 mg/L (25 deg C)
        Exper. Ref:  CHEM INSPECT TEST INST (1992)

 Water Sol Estimate from Fragments:
    Wat Sol (v1.01 est) =  6.5846 mg/L
    Wat Sol (Exper. database match) =  7.30
       Exper. Ref:  RICHARDSON,LT & MILLER,DM (1960)
    Wat Sol (Exper. database match) =  2.00
       Exper. Ref:  WEIL,L ET AL. (1974)
    Wat Sol (Exper. database match) =  0.24
       Exper. Ref:  WEIL,L ET AL. (1974)
    Wat Sol (Exper. database match) =  10.00
       Exper. Ref:  SHIU,WY ET AL (1990)
    Wat Sol (Exper. database match) =  8.00
       Exper. Ref:  CHEM INSPECT TEST INST (1992)

 ECOSAR Class Program (ECOSAR v0.99h):
    Class(es) found:
       Neutral Organics

 Henrys Law Constant (25 deg C) [HENRYWIN v3.10]:
   Bond Method :   2.56E-004  atm-m3/mole
   Group Method:   4.25E-011  atm-m3/mole
   Exper Database: 5.14E-06  atm-m3/mole
 Henrys LC [VP/WSol estimate using EPI values]:  4.788E-005 atm-m3/mole

 Log Octanol-Air Partition Coefficient (25 deg C) [KOAWIN v1.10]:
  Log Kow used:  4.14  (exp database)
  Log Kaw used:  -4.756  (exp database)
      Log Koa (KOAWIN v1.10 estimate):  8.896
      Log Koa (experimental database):  8.840

 Probability of Rapid Biodegradation (BIOWIN v4.10):
   Biowin1 (Linear Model)         :  -0.0593
   Biowin2 (Non-Linear Model)     :   0.0000
 Expert Survey Biodegradation Results:
   Biowin3 (Ultimate Survey Model):   1.5174  (recalcitrant)
   Biowin4 (Primary Survey Model) :   2.8245  (weeks       )
 MITI Biodegradation Probability:
   Biowin5 (MITI Linear Model)    :  -0.0719
   Biowin6 (MITI Non-Linear Model):   0.0000
 Anaerobic Biodegradation Probability:
   Biowin7 (Anaerobic Linear Model):  0.9848
 Ready Biodegradability Prediction:   NO

Hydrocarbon Biodegradation (BioHCwin v1.01):
    Structure incompatible with current estimation method!

 Sorption to aerosols (25 Dec C)[AEROWIN v1.00]:
  Vapor pressure (liquid/subcooled):  0.0344 Pa (0.000258 mm Hg)
  Log Koa (Exp database): 8.840
   Kp (particle/gas partition coef. (m3/ug)):
       Mackay model           :  8.72E-005 
       Octanol/air (Koa) model:  0.00017 
   Fraction sorbed to airborne particulates (phi):
       Junge-Pankow model     :  0.00314 
       Mackay model           :  0.00693 
       Octanol/air (Koa) model:  0.0134 

 Atmospheric Oxidation (25 deg C) [AopWin v1.92]:
   Hydroxyl Radicals Reaction:
      OVERALL OH Rate Constant =   0.5732 E-12 cm3/molecule-sec
      Half-Life =    18.659 Days (12-hr day; 1.5E6 OH/cm3)
   Ozone Reaction:
      No Ozone Reaction Estimation
   Fraction sorbed to airborne particulates (phi): 0.00503 (Junge,Mackay)
    Note: the sorbed fraction may be resistant to atmospheric oxidation

 Soil Adsorption Coefficient (PCKOCWIN v1.66):
      Koc    :  3380
      Log Koc:  3.529 

 Aqueous Base/Acid-Catalyzed Hydrolysis (25 deg C) [HYDROWIN v1.67]:
  Total Kb for pH > 8 at 25 deg C :  6.174E-012  L/mol-sec
  Kb Half-Life at pH 8: 3.558E+009  years  
  Kb Half-Life at pH 7: 3.558E+010  years  

 Bioaccumulation Estimates from Log Kow (BCFWIN v2.17):
   Log BCF from regression-based method = 2.488 (BCF = 307.5)
       log Kow used: 4.14 (expkow database)

 Volatilization from Water:
    Henry LC:  5.14E-006 atm-m3/mole  (Henry experimental database)
    Half-Life from Model River:        196  hours   (8.166 days)
    Half-Life from Model Lake :       2281  hours   (95.05 days)

 Removal In Wastewater Treatment:
    Total removal:              36.98  percent
    Total biodegradation:        0.37  percent
    Total sludge adsorption:    36.43  percent
    Total to Air:                0.18  percent
      (using 10000 hr Bio P,A,S)

 Level III Fugacity Model:
           Mass Amount    Half-Life    Emissions
            (percent)        (hr)       (kg/hr)
   Air       0.649           1.83e+003    1000       
   Water     6.14            4.32e+003    1000       
   Soil      89.4            8.64e+003    1000       
   Sediment  3.8             3.89e+004    0          
     Persistence Time: 4.72e+003 hr




                    

Click to predict properties on the Chemicalize site






Advertisement