Found 622 results

Search term: DATA_SOURCE in ('Pillbox')

ChemSpider 2D Image | Caffeine | C8H10N4O2

Caffeine

  • Molecular FormulaC8H10N4O2
  • Average mass194.191 Da
  • Monoisotopic mass194.080383 Da
  • ChemSpider ID2424

More details:



Featured data source



Validated by Experts, Validated by Users, Non-Validated, Removed by Users

1,3,7-trimethyl-2,3,6,7-tetrahydro-1H-purine-2,6-dione
1,3,7-Trimethyl-3,7-dihydro-1H-purin-2,6-dion [German] [ACD/IUPAC Name]
1,3,7-Trimethyl-3,7-dihydro-1H-purine-2,6-dione [ACD/IUPAC Name]
1,3,7-Triméthyl-3,7-dihydro-1H-purine-2,6-dione [French] [ACD/IUPAC Name]
1,3,7-Trimethylxanthine
1,3,7-trimetil-1H-purin-2,6-dione [Italian]
1,3,7-trimetilxantina [Italian]
1H-Purine-2,6-dione, 3,7-dihydro-1,3,7-trimethyl- [ACD/Index Name]
200-362-1 [EINECS]
200-659-6 [EINECS]
More...

Validated by Experts, Validated by Users, Non-Validated, Removed by Users

EV6475000 [DBID]
27602_FLUKA [DBID]
3G6A5W338E [DBID]
75035_FLUKA [DBID]
ACon1_000085 [DBID]
AI3-20154 [DBID]
AIDS001649 [DBID]
AIDS-001649 [DBID]
Bio1_000473 [DBID]
Bio1_000962 [DBID]
More...
  • References
  • Experimental Physico-chemical Properties
  • Predicted Physico-chemical Properties
  • Miscellaneous
    • Appearance:

      odourless white powder or crystals OU Chemical Safety Data (No longer updated) More details
    • Stability:

      Stable. Incompatible with strong acids, strong bases, strongoxidizing agents, iodine, silver salts, tannins. Weakly light sensitive in solution. OU Chemical Safety Data (No longer updated) More details
    • Toxicity:

      Organic Compound; Amide; Drug; Food Toxin; Central Nervous System Stimulant; Anorexigenic Agent; Appetite Depressant; Phosphodiesterase Inhibitor; Metabolite; Household Toxin; Natural Compound; Purinergic P1 Receptor Antagonist Toxin, Toxin-Target Database T3D2712
      ORL-RAT LD50 192 mg kg-1, IPR-RAT LD50 260 mg kg-1, IVN-RAT LD50 105 mg kg-1, SCU-RAT LD50 170 mg kg-1 OU Chemical Safety Data (No longer updated) More details
    • Safety:

      2 Alfa Aesar 39214, A10431
      22 Alfa Aesar 39214, A10431
      6.1 Alfa Aesar 39214, A10431
      DANGER: POISON, irritates skin, eyes, lungs Alfa Aesar 39214, A10431
      H302 Alfa Aesar 39214, A10431
      N06BC01 Wikidata Q60235
      P264-P270-P301+P312-P330-P501a Alfa Aesar 39214, A10431
      Safety glasses. OU Chemical Safety Data (No longer updated) More details
      Warning Alfa Aesar 39214, A10431
      WARNING: Causes CNS effects, skin and eye irritation Alfa Aesar 39214
    • Chemical Class:

      A trimethylxanthine in which the three methyl groups are located at positions 1, 3, and 7. A purine alkaloid that occurs naturally in tea and coffee. ChEBI CHEBI:27732
    • Bio Activity:

      7-TM Receptors Tocris Bioscience 2793
      A1 and A2B antagonist. CNS stimulant Tocris Bioscience 2793
      Adenosine Receptors Tocris Bioscience 2793
      Biochemicals & small molecules/Antagonists & inhibitors Hello Bio HB2846
      Central nervous system stimulant. Antagonist at A1 and A2A adenosine receptors and inhibitor of cyclic nucleotide phosphodiesterases. Mobilizes calcium from intracellular stores and inhibits benzodiaz epine binding to GABA receptors. Tocris Bioscience 2793
      Central nervous system stimulant. Antagonist at A1 and A2A adenosine receptors and inhibitor of cyclic nucleotide phosphodiesterases. Mobilizes calcium from intracellular stores and inhibits benzodiazepine binding to GABA receptors. Tocris Bioscience 2793
      Non-selective Adenosine Tocris Bioscience 2793
      Non-selective and competitive adenosine receptor antagonist (K<sub>i</sub> values are 27-30 and 50 &micro;M at A<sub>2</sub> and A<sub>1</sub> receptors respectively). Improves attention and memory. Also inhibits phosphodiesterase. Shows potential protective actions against dementia and age-related memory decline and anti-cancer actions. Hello Bio HB2846
      Non-selective, competitive adenosine receptor antagonist / PDE inhibitor Hello Bio HB2846
      Receptors & Transporters/G protein coupled receptors/Adenosine/Non-selective Hello Bio HB2846
  • Gas Chromatography
    • Retention Index (Kovats):

      1795 (estimated with error: 83) NIST Spectra mainlib_290714, replib_378377, replib_228814, replib_250547, replib_312821, replib_335205
      1820 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.2 mm; Column length: 12 m; Column type: Capillary; Heat rate: 30 K/min; Start T: 100 C; End T: 310 C; End time: 8 min; Start time: 3 min; CAS no: 58082; Active phase: HP-1; Carrier gas: He; Phase thickness: 0.33 um; Data type: Kovats RI; Authors: Bickeboeller-Friedrich, J.; Maurer, H.H., Screening for detection of new antidepressants, neuroleptics, hypnotics, and their metabolites in urine by GC-MS developed using rat liver microsomes, Ther. Drug Monit., 23(1), 2001, 61-70.) NIST Spectra nist ri
      1797 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column diameter: 0.22 mm; Column length: 25 m; Column type: Capillary; Start T: 200 C; CAS no: 58082; Active phase: BP-1; Carrier gas: N2; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Japp, M.; Gill, R.; Osselton, M.D., Comparison of drug retention indices determined on packed, wide bore capillary and narrow bore capillary columns, J. Forensic Sci., 32(6), 1987, 1574-1586.) NIST Spectra nist ri
      1803 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column diameter: 0.53 mm; Column length: 25 m; Column type: Capillary; Start T: 200 C; CAS no: 58082; Active phase: BP-1; Carrier gas: N2; Phase thickness: 1 um; Data type: Kovats RI; Authors: Japp, M.; Gill, R.; Osselton, M.D., Comparison of drug retention indices determined on packed, wide bore capillary and narrow bore capillary columns, J. Forensic Sci., 32(6), 1987, 1574-1586.) NIST Spectra nist ri
      1809 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 2 m; Column type: Packed; Start T: 180 C; CAS no: 58082; Active phase: SE-30; Carrier gas: N2; Substrate: 1% se-30 on Anachrom ABS(80-100mesh); Data type: Kovats RI; Authors: Musumarra, G.; Scarlata, G.; Romano, G.; Cappello, G.; Clementi, S.; Giulietti, G., Qualitative organic analysis. Part 2. Identification of drugs by principal components analysis of standardized TLC data in four eluent systems and of retention indices on SE 30, J. Anal. Toxicol., 11, 1987, 154-163.) NIST Spectra nist ri
      1824 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 1 m; Column type: Packed; Start T: 210 C; CAS no: 58082; Active phase: SE-30; Carrier gas: N2; Substrate: Inerton N AW (1), NaCl (2), and steel powder (3); Data type: Kovats RI; Authors: Lenchik, N.V.; Rudenko, B.A.; Dzhabarov, D.N., Gas chromatographic analysis of nitrogen-containing pharmaceticals using a thermoaerosol detector and non-porous sorbents, Zh. Anal. Khim., , 1986, 1438-1443.) NIST Spectra nist ri
      1832 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 1 m; Column type: Packed; Start T: 210 C; CAS no: 58082; Active phase: SE-30; Carrier gas: N2; Substrate: Inerton N AW (1), NaCl (2), and steel powder (3); Data type: Kovats RI; Authors: Lenchik, N.V.; Rudenko, B.A.; Dzhabarov, D.N., Gas chromatographic analysis of nitrogen-containing pharmaceticals using a thermoaerosol detector and non-porous sorbents, Zh. Anal. Khim., , 1986, 1438-1443.) NIST Spectra nist ri
      1840 (Program type: Isothermal; Col... (show more) umn class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Start T: 220 C; CAS no: 58082; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.2 um; Data type: Kovats RI; Authors: Phillips, A.M.; Logan, B.K.; Stafford, D.T., Further applications for capillary gas chromatography in routine quantitative toxicological analyses, J. Hi. Res. Chromatogr., 13, 1990, 754-758., Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column diameter: 0.20 mm; Column length: 25 m; Column type: Capillary; Start T: 250 C; CAS no: 58082; Active phase: SPB-1; Carrier gas: He; Data type: Kovats RI; Authors: Lora-Tamayo, C.; Rams, M.A.; Chacon, J.M.R., Gas Chromatographic Data for 187 Nitrogen- or Phosphorus-Containing Drugs and Metabolites of Toxicological Interest Analysed on Methyl Silicone Capillary Columns, J. Chromatogr., 374, 1986, 73-85.) NIST Spectra nist ri
      1780 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.49 mm; Column length: 25 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 100 C; End T: 275 C; End time: 15 min; Start time: 2 min; CAS no: 58082; Active phase: SE-30; Phase thickness: 1.14 um; Data type: Kovats RI; Authors: Schepers, P.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A., Applicability of capillary gas chromatography to substance identification in toxicology by means of retention indices, J. Forensic Sci., 27(1), 1982, 49-60.) NIST Spectra nist ri
      1796 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 6 ft; Column type: Packed; Start T: 190 C; CAS no: 58082; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb W; Data type: Kovats RI; Authors: Moller, M.R., Comparability of retention indices of polar substances at elevated temperatures, Chromatographia, 9(7), 1976, 311-314., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 300 C; End time: 12 min; Start time: 2 min; CAS no: 58082; Active phase: SE-30; Carrier gas: He; Phase thickness: 0.45 um; Data type: Kovats RI; Authors: Schepers, P.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A., Applicability of capillary gas chromatography to substance identification in toxicology by means of retention indices, J. Forensic Sci., 27(1), 1982, 49-60.) NIST Spectra nist ri
      1800 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 2 m; Column type: Packed; CAS no: 58082; Active phase: OV-1; Carrier gas: N2; Substrate: Chromosorb G, AW-DMCS; Data type: Kovats RI; Authors: Berninger, H.; Grunnagel, R.; Mall, S.; Moller, M.R., Gas chromatographic identification of unknown substances from body fluids by menas of retention indices, Beitr. Gerichtl. Med., 33, 1975, 185-191., Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 6 ft; Column type: Packed; CAS no: 58082; Active phase: OV-1; Carrier gas: N2; Substrate: Chromosorb G, AW-DMCS; Data type: Kovats RI; Authors: Berninger, H.; Grunnagel, R.; Mall, S.; Moller, M.R., Gas chromatographic identification of unknown substances from body fluids by menas of retention indices, Beitr. Gerichtl. Med., 33, 1975, 185-191., Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 6 ft; Column type: Packed; Start T: 200 C; CAS no: 58082; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G AW DMCS (80-100 mesh); Data type: Kovats RI; Authors: Moller, M.R., Comparability of retention indices of polar substances at elevated temperatures, Chromatographia, 9(7), 1976, 311-314., Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column type: Packed; Start T: 200 C; CAS no: 58082; Active phase: OV-1; Data type: Kovats RI; Authors: Berninger, H.; Moller, M.R., Retentionsindices zur gaschromatographischen Identifizierung von Arzneimitteln, Arch. Toxicol., 37, 1977, 295-305., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.28 mm; Column length: 70 m; Column type: Capillary; Heat rate: 2 K/min; Start T: 80 C; End T: 200 C; CAS no: 58082; Active phase: OV-101; Carrier gas: N2; Data type: Kovats RI; Authors: Yamaguchi, K.; Shibamoto, T., Volatile constituents of green tea, Gyokuro (Camellia sinensis L. var Yabukita), J. Agric. Food Chem., 29, 1981, 366-370.) NIST Spectra nist ri
      1802 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.28 mm; Column length: 70 m; Column type: Capillary; Heat rate: 2 K/min; Start T: 80 C; End T: 200 C; CAS no: 58082; Active phase: OV-101; Carrier gas: N2; Data type: Kovats RI; Authors: Yamaguchi, K.; Shibamoto, T., Volatile constituents of green tea, Gyokuro (Camellia sinensis L. var Yabukita), J. Agric. Food Chem., 29, 1981, 366-370.) NIST Spectra nist ri
      1818 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column type: Packed; Start T: 250 C; CAS no: 58082; Active phase: OV-1; Carrier gas: N2; Substrate: Chromosorb G; Data type: Kovats RI; Authors: Machata, G.; Vycudilik, W., Gas chromatographic analysis of illicit heroin samples, J. Anal. Toxicol., 4(6), 1980, 318-321.) NIST Spectra nist ri
      1830 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 6 ft; Column type: Packed; CAS no: 58082; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb W; Data type: Kovats RI; Authors: McLinden, V.J.; Stenhouse, A.M., A chromatography system for drug identification, Forensic Sci. Int., 13, 1979, 71-79.) NIST Spectra nist ri
      1789 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 2 m; Column type: Packed; Start T: 180 C; CAS no: 58082; Active phase: OV-1; Substrate: Chromosorb G; Data type: Kovats RI; Authors: Dubsky, H.; Hana, K.; Komarkova, M.; Rittich, B., Pouziti kovatsovych indexu pri toxikologickych analysach, Chem. Listy, 72, 1978, 980-984.) NIST Spectra nist ri
      1806 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 2 m; Column type: Packed; Start T: 200 C; CAS no: 58082; Active phase: OV-1; Substrate: Chromosorb G; Data type: Kovats RI; Authors: Dubsky, H.; Hana, K.; Komarkova, M.; Rittich, B., Pouziti kovatsovych indexu pri toxikologickych analysach, Chem. Listy, 72, 1978, 980-984.) NIST Spectra nist ri
      1805 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 6 ft; Column type: Packed; Start T: 200 C; CAS no: 58082; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G AW DMCS (80-100 mesh); Data type: Kovats RI; Authors: Moller, M.R., Comparability of retention indices of polar substances at elevated temperatures, Chromatographia, 9(7), 1976, 311-314.) NIST Spectra nist ri
      1810 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 2 m; Column type: Packed; CAS no: 58082; Active phase: SE-30; Data type: Kovats RI; Authors: Moffat, A.C.; Stead, A.H.; Smalldon, K.W., Optimum use of paper, thin-layer and gas-liquid chromatography for the identification of basic drugs. III. Gas-liquid chromatography, J. Chromatogr., 90, 1974, 19-33., Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 6 ft; Column type: Packed; Start T: 200 C; CAS no: 58082; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G AW DMCS (80-100 mesh); Data type: Kovats RI; Authors: Moller, M.R., Comparability of retention indices of polar substances at elevated temperatures, Chromatographia, 9(7), 1976, 311-314.) NIST Spectra nist ri
      1833 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 6 ft; Column type: Packed; Start T: 230 C; CAS no: 58082; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb W; Data type: Kovats RI; Authors: Moller, M.R., Comparability of retention indices of polar substances at elevated temperatures, Chromatographia, 9(7), 1976, 311-314.) NIST Spectra nist ri
      3002 (Program type: Isothermal; Col... (show more) umn class: Standard polar; Column type: Packed; Start T: 220 C; CAS no: 58082; Active phase: PEG-20M; Substrate: Chromosorb W; Data type: Kovats RI; Authors: Donike, M.; Stratmann, D., Gas-chromatographische identifizierung von stimulantien der phenylathylaminreihe mit hilfe der retnetions-indices, Z. Anal. Chem., 279(2), 1976, 129-131.) NIST Spectra nist ri
    • Retention Index (Lee):

      306.6 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.2 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 300 C; End time: 5 min; Start time: 2 min; CAS no: 58082; Active phase: DB-1; Phase thickness: 0.25 um; Data type: Lee RI; Authors: Johnson, C.I.; Urso, A.; Geleta, L., Broad spectrum analysis of municipal and industrial effluents discharged into the Peace, Athabasca and Slave river basins: characterization of effluent samples, 1994 - Volume 1 of 2, Northern River Basins Study Project Report No. 121, Norther River Basins Study, Edmonton, Alberta, 1997, 27.) NIST Spectra nist ri
    • Retention Index (Normal Alkane):

      1810 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 6 ft; Column type: Packed; Start T: 200 C; CAS no: 58082; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G AW DMCS (80-100 mesh); Data type: Normal alkane RI; Authors: Moller, M.R., Comparability of retention indices of polar substances at elevated temperatures, Chromatographia, 9(7), 1976, 311-314., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; CAS no: 58082; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.53 mm; Column length: 10 m; Column type: Capillary; CAS no: 58082; Active phase: CP Sil 5 CB; Phase thickness: 5.2 um; Data type: Normal alkane RI; Authors: Bogusz, M.; Bialka, J.; Gierz, J.; Klys, M., Use of short, wide-bore capillary columns in GC toxicological screening, J. Anal. Toxicol., 10(4), 1986, 135-138., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 2 m; Column type: Packed; Start T: 100 C; End T: 300 C; CAS no: 58082; Active phase: Polydimethyl siloxane; Carrier gas: Nitrogen; Data type: Normal alkane RI; Authors: MHA, Directorate of ForensicScience., Forensic Toxicology, 9999., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 2 m; Column type: Packed; Start T: 100 C; End T: 300 C; CAS no: 58082; Active phase: SE-30; Carrier gas: Nitrogen; Substrate: Chromosorb G AW DMCS (80-100 mesh); Data type: Normal alkane RI; Authors: MHA, Directorate of ForensicScience., Forensic Toxicology, 9999., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Other; CAS no: 58082; Active phase: Methyl Silicone; Data type: Normal alkane RI; Authors: Ardrey, R.E.; Moffat, A.C., Gas-liquid chromatographic retention indices of 1318 substances of toxicological interest on SE-30 or OV-1 stationary phase, J. Chromatogr., 220, 1981, 195-252.) NIST Spectra nist ri
      1760 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.20 mm; Column length: 12 m; Column type: Capillary; CAS no: 58082; Active phase: Polymethylsiloxane, (PMS-20000); Carrier gas: He; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Gambaro, V.; Saligari, E.; Froldi, R.; Bianchi, L., Analysis of street drugs by means of HRGC, Bollettino Chimico Farmaceutica, 36(4), 1997, 359-367.) NIST Spectra nist ri
      1771 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.20 mm; Column length: 12 m; Column type: Capillary; CAS no: 58082; Active phase: Polymethylsiloxane, (PMS-20000); Carrier gas: He; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Gambaro, V.; Saligari, E.; Froldi, R.; Bianchi, L., Analysis of street drugs by means of HRGC, Bollettino Chimico Farmaceutica, 36(4), 1997, 359-367.) NIST Spectra nist ri
      1800 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.20 mm; Column length: 12 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 160 C; End T: 300 C; CAS no: 58082; Active phase: Polymethylsiloxane, (PMS-20000); Carrier gas: He; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Gambaro, V.; Saligari, E.; Froldi, R.; Bianchi, L., Analysis of street drugs by means of HRGC, Bollettino Chimico Farmaceutica, 36(4), 1997, 359-367., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Heat rate: 25 K/min; Start T: 120 C; End T: 270 C; CAS no: 58082; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32.) NIST Spectra nist ri
      1768.6 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Heat rate: 13 K/min; Start T: 85 C; End T: 250 C; Start time: 0.5 min; CAS no: 58082; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Meatherall, R., Rapid GC-MS confirmation of urinary amphetamine and methamphetamine as their propylchloroformate derivatives, J. Anal. Toxicol., 19, 1995, 316-322.) NIST Spectra nist ri
      1808.3 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.75 mm; Column length: 30 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 155 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 58082; Active phase: SPB-1; Carrier gas: He; Phase thickness: 10 um; Data type: Normal alkane RI; Authors: Coudore, F.; Alazard, J.-M.; Paire, M.; Andraud, G.; Lavarenne, J., Rapid toxicological screening of barbiturates in plasma by wide-bore capillary gas chromatography and nitrogen-phosphorus detection, J. Anal. Toxicol., 17, 1993, 109-113.) NIST Spectra nist ri
      1799.2 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.2 mm; Column length: 12.5 m; Column type: Capillary; Heat rate: 25 K/min; Start T: 50 C; End T: 250 C; End time: 5 min; Start time: 2 min; CAS no: 58082; Active phase: Ultra-1; Carrier gas: N2; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Georgakopoulos, C.G.; Kiburis, J.C.; Jurs, P.C., Prediction of Gas Chromatographic Relative Retention Times of Stimulants and Narcotics, Anal. Chem., 63(18), 1991, 2021-2024.) NIST Spectra nist ri
      1827.7 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 12 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 40 C; End T: 290 C; Start time: 1 min; CAS no: 58082; Active phase: SE-30; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Neill, G.P.; Davies, N.W.; McLean, S., Automated screening procedure using gas chromatography-mass spectrometry for identification of drugs after their extraction from biological samples, J. Chromatogr., 565, 1991, 207-224.) NIST Spectra nist ri
      1786.1 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.26 mm; Column length: 30 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 280 C; End time: 22 min; Start time: 1 min; CAS no: 58082; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Manca, D.; Ferron, L.; Weber, J-P., A System for Toxicological Screening by Capillary Gas Chromatography with Use of Drug Retention Index Based on Nitrogen-Containing Reference Compounds, Clin. Chem., 35(4), 1989, 601-607.) NIST Spectra nist ri
      1786.9 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.26 mm; Column length: 30 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 280 C; End time: 22 min; Start time: 1 min; CAS no: 58082; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Manca, D.; Ferron, L.; Weber, J-P., A System for Toxicological Screening by Capillary Gas Chromatography with Use of Drug Retention Index Based on Nitrogen-Containing Reference Compounds, Clin. Chem., 35(4), 1989, 601-607.) NIST Spectra nist ri
      1795.9 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 1.1 m; Column type: Packed; Heat rate: 8.5 K/min; Start T: 50 C; End T: 300 C; CAS no: 58082; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb W HP; Data type: Normal alkane RI; Authors: Saxton, W.L., Emergence temperature indices and relative retention times of pesticides and industrial chemicals determined by linear programmed temperature gas chromatography, J. Chromatogr., 393, 1987, 175-194.) NIST Spectra nist ri
      1774 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 130 C; End T: 290 C; End time: 10 min; Start time: 1 min; CAS no: 58082; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Sharp, M.E., A rapid screening procedure for acidic and neutral drugs in blood by high resolution gas chromatography, J. Anal. Toxicol., 11, 1987, 8-11.) NIST Spectra nist ri
      1820 (Program type: Complex; Column... (show more) class: Standard non-polar; Column diameter: 0.53 mm; Column length: 10 m; Column type: Capillary; Description: 100 0C (2 min) ^ 20 0C/min -> 180 0C ^ 7.5 0C/min -> 280 0C (6 min); CAS no: 58082; Active phase: CP Sil 5 CB; Phase thickness: 5.2 um; Data type: Normal alkane RI; Authors: Bogusz, M.; Bialka, J.; Gierz, J.; Klys, M., Use of short, wide-bore capillary columns in GC toxicological screening, J. Anal. Toxicol., 10(4), 1986, 135-138.) NIST Spectra nist ri
      1764 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Heat rate: 20 K/min; Start T: 50 C; End T: 300 C; CAS no: 58082; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32.) NIST Spectra nist ri
      1768 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 280 C; CAS no: 58082; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32.) NIST Spectra nist ri
      1775 (Program type: Complex; Column... (show more) class: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Description: 120 0X ^ 8 0C/min -> 270 0C ^ 25 0C/min -> 300 0C (5 min); CAS no: 58082; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 270 C; CAS no: 58082; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32.) NIST Spectra nist ri
      1776 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Heat rate: 6 K/min; Start T: 120 C; End T: 270 C; CAS no: 58082; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32.) NIST Spectra nist ri
      1779 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Heat rate: 12 K/min; Start T: 120 C; End T: 270 C; CAS no: 58082; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32.) NIST Spectra nist ri
      1784 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Heat rate: 15 K/min; Start T: 120 C; End T: 270 C; CAS no: 58082; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32.) NIST Spectra nist ri
      1815 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 2 m; Column type: Packed; Heat rate: 2.5 K/min; Start T: 120 C; End T: 200 C; CAS no: 58082; Active phase: SE-30; Substrate: Gas Chrom P; Data type: Normal alkane RI; Authors: Marozzi, E.; Gambaro, V.; Saligari, E.; Mariani, R.; Lodi, F., Use of the retention index in gas chromatographic studies of drugs, J. Anal. Toxicol., 6, 1982, 185-192.) NIST Spectra nist ri
      1810.7 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 2 m; Column type: Packed; Heat rate: 10 K/min; Start T: 220 C; End T: 270 C; CAS no: 58082; Active phase: OV-101; Substrate: Chromosorb (100-120 mesh); Data type: Normal alkane RI; Authors: Cailleux, A.; Turcant, A.; Premel-Cabic, A.; Allain, P., Identification and Quantitation of Neutral and Basic Drugs in Blood By Gas Chromatography and Mass Spectrometry, J. Chromatogr. Sci., 19, 1981, 163-176.) NIST Spectra nist ri
      1813.9 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.205 mm; Column length: 25 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 110 C; End T: 230 C; End time: 5 min; CAS no: 58082; Active phase: SP-2100; Carrier gas: N2; Data type: Normal alkane RI; Authors: Kinberger, B.; Holmen, A.; Wahrgren, P., Determination of barbiturates and some neutral drugs in serum using quartz glass capillary gas chromatography, J. Chromatogr., 224, 1981, 449-455.) NIST Spectra nist ri
      1797 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.3 mm; Column length: 30 m; Column type: Capillary; Heat rate: 2 K/min; Start T: 80 C; End T: 275 C; Start time: 7 min; CAS no: 58082; Active phase: OV-101; Carrier gas: H2; Data type: Normal alkane RI; Authors: Pinkston, D.; Spiteller, G.; von Henning, H.; Matthaei, D., High-resolution gas chromatography-mass spectrometry of the methyl esters of organic acids from uremic hemofiltrates, J. Chromatogr., 223, 1981, 1-19., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 25 m; Column type: Capillary; Heat rate: 2 K/min; Start T: 75 C; End T: 280 C; Start time: 7 min; CAS no: 58082; Active phase: OV-101; Carrier gas: He; Data type: Normal alkane RI; Authors: Spiteller, M.; Spiteller, G., Trennung und charakterisierung saurer harnbest and- teile, J. Chromatogr., 164, 1979, 253-317.) NIST Spectra nist ri
      1790 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 6 ft; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 58082; Active phase: SE-30; Carrier gas: N2; Substrate: Chromosorb W AW DMS; Data type: Normal alkane RI; Authors: Peel, H.W.; Perrigo, B., A practical gas chromatographic screening procedure for toxicological analysis, Can.Soc.Forens.Sci.J., 9(2), 1975, 69-74., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 6 ft; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 58082; Active phase: SE-30; Carrier gas: Nitrogen; Substrate: Chromosorb W AW DMS (80-100 mesh); Data type: Normal alkane RI; Authors: Peel, H.W.; Perrigo, B., A practical gas chromatographic screening procedure for toxicological analysis, Can. Soc. Forens. Sci. J., 9(2), 1976, 69-74.) NIST Spectra nist ri
      1836 (Program type: Ramp; Column cl... (show more) ass: Semi-standard non-polar; Column diameter: 0.18 mm; Column length: 10 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 40 C; End T: 295 C; Start time: 1.5 min; CAS no: 58082; Active phase: SLB-5MS; Carrier gas: Helium; Phase thickness: 0.18 um; Data type: Normal alkane RI; Authors: Risticevic, S.; Carasek, E.; Pawliszyn, J., Headspace solid-phase microextraction-gas chromatographic-time-of-flight mass spectrometric methodology for geographical origin verification of coffee, Anal. Chim. Acta, 617, 2008, 72-84.) NIST Spectra nist ri
      1837 (Program type: Ramp; Column cl... (show more) ass: Semi-standard non-polar; Column diameter: 0.18 mm; Column length: 10 m; Column type: Capillary; CAS no: 58082; Active phase: SLB-5MS; Carrier gas: Helium; Phase thickness: 0.18 um; Data type: Normal alkane RI; Authors: Risticevic, S.; Carasek, E.; Pawliszyn, J., Headspace solid-phase microextraction-gas chromatographic-time-of-flight mass spectrometric methodology for geographical origin verification of coffee, Anal. Chim. Acta, 617, 2008, 72-84.) NIST Spectra nist ri
      1833.7 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 15 m; Column type: Capillary; Description: 100 0C (0.4 min) ^ 25 0C/min -> 200 0C ^ 10 0C/min -> 290 0C (10 min); CAS no: 58082; Active phase: HG-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Rasanen, I.; Kontinen, I.; Nokua, J.; Ojanpera, I.; Vuori, E., Precise gas chromatography with retention time locking in comprehensive toxicological screening for drugs in blood, J. Chromatogr. B, 788, 2003, 243-250.) NIST Spectra nist ri
      1808.4 (Program type: Ramp; Column cl... (show more) ass: Semi-standard non-polar; Column diameter: 0.53 mm; Column length: 15 m; Column type: Capillary; Heat rate: 15 K/min; Start T: 90 C; End T: 320 C; CAS no: 58082; Active phase: DB-5; Carrier gas: He; Phase thickness: 1.5 um; Data type: Normal alkane RI; Authors: Takeda, A.; Tanaka, H.; Shinohara, T.; Ohtake, I., Systematic analysis of acid, neutral and basic drugs in horse plasma by combination of solid-phase extraction, non-aqueous partitioning and gas chromatography-mass spectrometry, J. Chromatogr. B, 758, 2001, 235-248.) NIST Spectra nist ri
      1817.6 (Program type: Ramp; Column cl... (show more) ass: Semi-standard non-polar; Column diameter: 0.2 mm; Column length: 12.5 m; Column type: Capillary; Heat rate: 25 K/min; Start T: 75 C; End T: 320 C; End time: 2 min; CAS no: 58082; Active phase: Ultra-2; Phase thickness: 0.11 um; Data type: Normal alkane RI; Authors: Hemmersbach, P.; de la Torre, R., Review. Stimulants, narcotics and .beta.-blockers: 25 years of development in analytical techniques for doping control, J. Chromatogr. B, 687, 1996, 221-238.) NIST Spectra nist ri
      1822.1 (Program type: Ramp; Column cl... (show more) ass: Semi-standard non-polar; Column diameter: 0.2 mm; Column length: 12.5 m; Column type: Capillary; Heat rate: 25 K/min; Start T: 75 C; End T: 320 C; End time: 2 min; CAS no: 58082; Active phase: Ultra-2; Phase thickness: 0.11 um; Data type: Normal alkane RI; Authors: Hemmersbach, P.; de la Torre, R., Review. Stimulants, narcotics and .beta.-blockers: 25 years of development in analytical techniques for doping control, J. Chromatogr. B, 687, 1996, 221-238.) NIST Spectra nist ri
      1829.3 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 15 m; Column type: Capillary; Description: 70 0C (0.7 min) ^ 20 0C/min -> 140 0C ^ 10 0C/min -> 290 0C (9.5 min); CAS no: 58082; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Rasanen, I.; Ojanpera, I.; Vartiovaara, J.; Vuori, E.; Sunila, P., The advantage of dual-column approach and retention indices combined with refined reporting in gas chromatographic drug screening, J. Hi. Res. Chromatogr., 19, 1996, 313-321.) NIST Spectra nist ri
      1846.2 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 15 m; Column type: Capillary; Description: 70 0C (0.7 min) ^ 20 0C/min -> 140 0C ^ 10 0C/min -> 290 0C (9.5 min); CAS no: 58082; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Rasanen, I.; Ojanpera, I.; Vartiovaara, J.; Vuori, E.; Sunila, P., The advantage of dual-column approach and retention indices combined with refined reporting in gas chromatographic drug screening, J. Hi. Res. Chromatogr., 19, 1996, 313-321.) NIST Spectra nist ri
      1806.2 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 25 m; Column type: Capillary; Description: 70 0C (0.7 min) ^ 20 0C/min -> 140 0C ^ 10 0C/min -> 280 0C (4 min); CAS no: 58082; Active phase: NB-54; Carrier gas: He; Phase thickness: 0.10 um; Data type: Normal alkane RI; Authors: Ojanpera, I.; Rasanen, I.; Vuori, E., Automated quantitative screening for acidic and neutral drugs in whole blood by dual-column capillary gas chromatography, J. Anal. Toxicol., 15, 1991, 204-208.) NIST Spectra nist ri
      1832.9 (Program type: Ramp; Column cl... (show more) ass: Semi-standard non-polar; Column diameter: 0.2 mm; Column length: 17 m; Column type: Capillary; Heat rate: 20 K/min; Start T: 100 C; End T: 300 C; End time: 4 min; CAS no: 58082; Active phase: SE-54; Carrier gas: He; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Lho, D.-S.; Shin, H.-S.; Kang, B.-K.; Park, J., Systematic analysis of stimulants and narcotic analgesics by gas chromatography with nitrogen specific detection and mass spectrometry, J. Anal. Toxicol., 14, 1990, 73-76.) NIST Spectra nist ri
      1836.5 (Program type: Ramp; Column cl... (show more) ass: Semi-standard non-polar; Column diameter: 0.2 mm; Column length: 17 m; Column type: Capillary; Heat rate: 20 K/min; Start T: 100 C; End T: 300 C; End time: 4 min; CAS no: 58082; Active phase: SE-54; Carrier gas: He; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Lho, D.-S.; Shin, H.-S.; Kang, B.-K.; Park, J., Systematic analysis of stimulants and narcotic analgesics by gas chromatography with nitrogen specific detection and mass spectrometry, J. Anal. Toxicol., 14, 1990, 73-76.) NIST Spectra nist ri
      1820.9 (Program type: Ramp; Column cl... (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 12.5 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 110 C; End T: 290 C; End time: 6.5 min; Start time: 1 min; CAS no: 58082; Active phase: Ultra-2; Phase thickness: 0.5 um; Data type: Normal alkane RI; Authors: Watts, V.W.; Simonick, T.F., A retention index library for commonly encountered drugs and metabolites using tri-n-alkylamines as reference compounds, nitrogen-phosphorus detectors, and dual capillary chromatography, J. Anal. Toxicol., 11, 1987, 210-214.) NIST Spectra nist ri
      1820.8 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.20 mm; Column length: 30 m; Column type: Capillary; Description: 50 0C (1 min) ^ 8 0C/min (9 min) ^ 6 0C/min -> 300 0C; CAS no: 58082; Active phase: SE-54; Data type: Normal alkane RI; Authors: Liu, R.H.; Ku, W.W.; Fitzgerald, M.P., Separation and characterization of amine drugs and their enantiomers by capillary column gas chromatography-mass spectrometry, J. Ass. Offic. Anal. Chem, 66(6), 1983, 1443-1446.) NIST Spectra nist ri
    • Retention Index (Linear):

      1760 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.2 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 300 C; End time: 5 min; Start time: 2 min; CAS no: 58082; Active phase: DB-1; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Johnson, C.I.; Urso, A.; Geleta, L., Broad spectrum analysis of municipal and industrial effluents discharged into the Peace, Athabasca and Slave river basins: characterization of effluent samples, 1994 - Volume 1 of 2, Northern River Basins Study Project Report No. 121, Norther River Basins Study, Edmonton, Alberta, 1997, 27.) NIST Spectra nist ri
      1768 (Program type: Complex; Column... (show more) class: Standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Description: 50C(2min)=>(20C/min)=>120C=>(7C/min)=>310C(10min); CAS no: 58082; Active phase: OV-101; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Yasuhara, A.; Shiraishi, H.; Nishikawa, M.; Yamamoto, T.; Uehiro, T.; Nakasugi, O.; Okumura, T.; Kenmotsu, K.; Fukui, H.; Nagase, M.; Ono, Y.; Kawagoshi, Y.; Baba, K.; Noma, Y., Determination of organic components in leachates from hazardous waste disposal sites in Japan by gas chromatography-mass spectrometry, J. Chromatogr. A, 774, 1997, 321-332., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 280 C; End time: 5 min; CAS no: 58082; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Perrigo, B.J.; Ballantyne, D.J.; Peel, H.W., Condierations in developing a data base for drugs on a DBI capillary column, J. Can. Soc. Forensic Sci., 17(2), 1984, 41-49., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 15 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 280 C; End time: 5 min; CAS no: 58082; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Perrigo, B.J.; Peel, H.W.; Ballantyne, D.J., Use of Dual-Column Fused-Silica Capillary Gas Chromatography in Combination with Detector Response Factors for Analytical Toxicology., J. Chromatogr., 341, 1985, 81-88.) NIST Spectra nist ri
      1809 (Program type: Complex; Column... (show more) class: Standard non-polar; Column diameter: 0.53 mm; Column length: 10 m; Column type: Capillary; Description: 100 0C (2 min ) ^ 15 0C/min -> 200 0C ^ 10 0C/min -> 300 0C (8 min hold); CAS no: 58082; Active phase: CP Sil 5 CB; Carrier gas: He; Phase thickness: 5.0 um; Data type: Linear RI; Authors: Aderjan, R.; Bogusz, M., Nitroalkanes as a multidetector retention index scale for drug identification in gas chromatography, J. Chromatogr., 454, 1988, 345-351.) NIST Spectra nist ri
      1811 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.75 mm; Column length: 30 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 160 C; End T: 280 C; End time: 12 min; CAS no: 58082; Active phase: SPB-1; Carrier gas: He; Phase thickness: 1.0 um; Data type: Linear RI; Authors: Christ, D.W.; Noomano, P.; Rosas, M.; Rhone, D., Retention indices by wide-bore capillary gas chromatography with nitrogen-phosphorus detection, J. Anal. Toxicol., 12, 1988, 84-88.) NIST Spectra nist ri
      1769 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.53 mm; Column length: 12 m; Column type: Capillary; Heat rate: 6 K/min; Start T: 120 C; End T: 250 C; CAS no: 58082; Active phase: CBP-1; Carrier gas: N2; Data type: Linear RI; Authors: Oyama, N.; Sano, T.; Syoyama, M.; Maeda, K., Studies on systematic analysis of poisonous compounds in forensic chemistry. II. Application of capillary column gas chromatography to substance identification by means of retention indices, Eisei Kagaku, 33(5), 1987, 342-348.) NIST Spectra nist ri
      1775 (Program type: Complex; Column... (show more) class: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Description: 120C=>8C/min=>270C=>25C/min=>300C; CAS no: 58082; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Stowell, A.; Wilson, L.W., A simple approach to the interlaboratory transfer of drug retention indices determined by temperature programmed capillary gas chromatography, J. Forensic Sci., 32(5), 1987, 1214-1220., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Heat rate: 12 K/min; Start T: 120 C; End T: 280 C; End time: 5 min; CAS no: 58082; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Perrigo, B.J.; Ballantyne, D.J.; Peel, H.W., Condierations in developing a data base for drugs on a DBI capillary column, J. Can. Soc. Forensic Sci., 17(2), 1984, 41-49.) NIST Spectra nist ri
      1796 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 58082; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri
      1798 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 58082; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri
      1800 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 1.8 m; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 58082; Active phase: SE-30; Carrier gas: N2; Substrate: Chromosorb W; Data type: Linear RI; Authors: Perrigo, B.J.; Peel, H.W., The use of retention indices and temperature-programmed gas chromatography in analytical toxicology, J. Chromatogr. Sci., 19, 1981, 219-226., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 58082; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri
      1802 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 58082; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri
      1805 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 58082; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri
      1807 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 58082; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri
      1810 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 58082; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri
      1813 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 58082; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri
      1815 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 58082; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri
      1818 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 58082; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri
      1830 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 58082; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri
      1835 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 58082; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri
      1850 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 58082; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri
      1764 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.2 mm; Column length: 12 m; Column type: Capillary; Heat rate: 20 K/min; Start T: 50 C; End T: 300 C; End time: 3 min; Start time: 1 min; CAS no: 58082; Active phase: Methyl Silicone; Carrier gas: He; Phase thickness: 0.33 um; Data type: Linear RI; Authors: Newton, B.; Foery, R.F., Retention indices and dual capillary gas chromatography for rapid identification of sedative hypnotic drugs in emergency toxicology, J. Anal. Toxicol., 8, 1984, 129-134.) NIST Spectra nist ri
      1761 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 120 C; End T: 280 C; End time: 5 min; CAS no: 58082; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Perrigo, B.J.; Ballantyne, D.J.; Peel, H.W., Condierations in developing a data base for drugs on a DBI capillary column, J. Can. Soc. Forensic Sci., 17(2), 1984, 41-49.) NIST Spectra nist ri
      1778 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Heat rate: 15 K/min; Start T: 120 C; End T: 280 C; End time: 5 min; CAS no: 58082; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Perrigo, B.J.; Ballantyne, D.J.; Peel, H.W., Condierations in developing a data base for drugs on a DBI capillary column, J. Can. Soc. Forensic Sci., 17(2), 1984, 41-49.) NIST Spectra nist ri
      1838 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.31 mm; Column length: 25 m; Column type: Capillary; Description: 50C(2min)=>(20C/min)=>120C=>(7C/min)=>310C(10min); CAS no: 58082; Active phase: 5 % Phenyl methyl siloxane; Carrier gas: He; Phase thickness: 0.52 um; Data type: Linear RI; Authors: Yasuhara, A.; Shiraishi, H.; Nishikawa, M.; Yamamoto, T.; Uehiro, T.; Nakasugi, O.; Okumura, T.; Kenmotsu, K.; Fukui, H.; Nagase, M.; Ono, Y.; Kawagoshi, Y.; Baba, K.; Noma, Y., Determination of organic components in leachates from hazardous waste disposal sites in Japan by gas chromatography-mass spectrometry, J. Chromatogr. A, 774, 1997, 321-332.) NIST Spectra nist ri
      1848 (Program type: Ramp; Column cl... (show more) ass: Semi-standard non-polar; Column diameter: 0.2 mm; Column length: 12 m; Column type: Capillary; Heat rate: 20 K/min; Start T: 50 C; End T: 300 C; End time: 3 min; Start time: 1 min; CAS no: 58082; Active phase: 5 % Phenyl methyl siloxane; Carrier gas: He; Phase thickness: 0.33 um; Data type: Linear RI; Authors: Newton, B.; Foery, R.F., Retention indices and dual capillary gas chromatography for rapid identification of sedative hypnotic drugs in emergency toxicology, J. Anal. Toxicol., 8, 1984, 129-134.) NIST Spectra nist ri

Predicted data is generated using the ACD/Labs Percepta Platform - PhysChem Module, version: 14.00

Density: 1.5±0.1 g/cm3
Boiling Point: 416.8±37.0 °C at 760 mmHg
Vapour Pressure: 0.0±1.0 mmHg at 25°C
Enthalpy of Vaporization: 67.0±3.0 kJ/mol
Flash Point: 205.9±26.5 °C
Index of Refraction: 1.679
Molar Refractivity: 50.4±0.5 cm3
#H bond acceptors: 6
#H bond donors: 0
#Freely Rotating Bonds: 0
#Rule of 5 Violations: 0
ACD/LogP: -0.13
ACD/LogD (pH 5.5): 0.28
ACD/BCF (pH 5.5): 1.00
ACD/KOC (pH 5.5): 34.00
ACD/LogD (pH 7.4): 0.28
ACD/BCF (pH 7.4): 1.00
ACD/KOC (pH 7.4): 34.00
Polar Surface Area: 58 Å2
Polarizability: 20.0±0.5 10-24cm3
Surface Tension: 55.8±7.0 dyne/cm
Molar Volume: 133.4±7.0 cm3

Predicted data is generated using the US Environmental Protection Agency�s EPISuite™

                        
 Log Octanol-Water Partition Coef (SRC):
    Log Kow (KOWWIN v1.67 estimate) =  0.16
    Log Kow (Exper. database match) =  -0.07
       Exper. Ref:  Hansch,C et al. (1995)

 Boiling Pt, Melting Pt, Vapor Pressure Estimations (MPBPWIN v1.42):
    Boiling Pt (deg C):  430.85  (Adapted Stein & Brown method)
    Melting Pt (deg C):  180.30  (Mean or Weighted MP)
    VP(mm Hg,25 deg C):  7.33E-009  (Modified Grain method)
    MP  (exp database):  238 deg C
    Subcooled liquid VP: 1.46E-006 mm Hg (25 deg C, Mod-Grain method)

 Water Solubility Estimate from Log Kow (WSKOW v1.41):
    Water Solubility at 25 deg C (mg/L):  2632
       log Kow used: -0.07 (expkow database)
       no-melting pt equation used
     Water Sol (Exper. database match) =  2.16e+004 mg/L (25 deg C)
        Exper. Ref:  YALKOWSKY,SH & DANNENFELSER,RM (1992)

 Water Sol Estimate from Fragments:
    Wat Sol (v1.01 est) =  11308 mg/L
    Wat Sol (Exper. database match) =  21600.00
       Exper. Ref:  YALKOWSKY,SH & DANNENFELSER,RM (1992)

 ECOSAR Class Program (ECOSAR v0.99h):
    Class(es) found:
       Imides
       Imidazoles

 Henrys Law Constant (25 deg C) [HENRYWIN v3.10]:
   Bond Method :   3.58E-011  atm-m3/mole
   Group Method:   Incomplete
 Henrys LC [VP/WSol estimate using EPI values]:  7.116E-013 atm-m3/mole

 Log Octanol-Air Partition Coefficient (25 deg C) [KOAWIN v1.10]:
  Log Kow used:  -0.07  (exp database)
  Log Kaw used:  -8.835  (HenryWin est)
      Log Koa (KOAWIN v1.10 estimate):  8.765
      Log Koa (experimental database):  None

 Probability of Rapid Biodegradation (BIOWIN v4.10):
   Biowin1 (Linear Model)         :   0.6551
   Biowin2 (Non-Linear Model)     :   0.5625
 Expert Survey Biodegradation Results:
   Biowin3 (Ultimate Survey Model):   2.7700  (weeks       )
   Biowin4 (Primary Survey Model) :   3.5676  (days-weeks  )
 MITI Biodegradation Probability:
   Biowin5 (MITI Linear Model)    :   0.1439
   Biowin6 (MITI Non-Linear Model):   0.0521
 Anaerobic Biodegradation Probability:
   Biowin7 (Anaerobic Linear Model):  0.5019
 Ready Biodegradability Prediction:   NO

Hydrocarbon Biodegradation (BioHCwin v1.01):
    Structure incompatible with current estimation method!

 Sorption to aerosols (25 Dec C)[AEROWIN v1.00]:
  Vapor pressure (liquid/subcooled):  0.000195 Pa (1.46E-006 mm Hg)
  Log Koa (Koawin est  ): 8.765
   Kp (particle/gas partition coef. (m3/ug)):
       Mackay model           :  0.0154 
       Octanol/air (Koa) model:  0.000143 
   Fraction sorbed to airborne particulates (phi):
       Junge-Pankow model     :  0.358 
       Mackay model           :  0.552 
       Octanol/air (Koa) model:  0.0113 

 Atmospheric Oxidation (25 deg C) [AopWin v1.92]:
   Hydroxyl Radicals Reaction:
      OVERALL OH Rate Constant =  19.4185 E-12 cm3/molecule-sec
      Half-Life =     0.551 Days (12-hr day; 1.5E6 OH/cm3)
      Half-Life =     6.610 Hrs
   Ozone Reaction:
      No Ozone Reaction Estimation
   Fraction sorbed to airborne particulates (phi): 0.455 (Junge,Mackay)
    Note: the sorbed fraction may be resistant to atmospheric oxidation

 Soil Adsorption Coefficient (PCKOCWIN v1.66):
      Koc    :  10
      Log Koc:  1.000 

 Aqueous Base/Acid-Catalyzed Hydrolysis (25 deg C) [HYDROWIN v1.67]:
    Rate constants can NOT be estimated for this structure!

 Bioaccumulation Estimates from Log Kow (BCFWIN v2.17):
   Log BCF from regression-based method = 0.500 (BCF = 3.162)
       log Kow used: -0.07 (expkow database)

 Volatilization from Water:
    Henry LC:  3.58E-011 atm-m3/mole  (estimated by Bond SAR Method)
    Half-Life from Model River: 2.279E+007  hours   (9.496E+005 days)
    Half-Life from Model Lake : 2.486E+008  hours   (1.036E+007 days)

 Removal In Wastewater Treatment:
    Total removal:               1.85  percent
    Total biodegradation:        0.09  percent
    Total sludge adsorption:     1.76  percent
    Total to Air:                0.00  percent
      (using 10000 hr Bio P,A,S)

 Level III Fugacity Model:
           Mass Amount    Half-Life    Emissions
            (percent)        (hr)       (kg/hr)
   Air       0.00382         13.2         1000       
   Water     38.6            360          1000       
   Soil      61.4            720          1000       
   Sediment  0.0711          3.24e+003    0          
     Persistence Time: 581 hr




                    

Click to predict properties on the Chemicalize site






Advertisement