ChemSpider 2D Image | meprobamate | C9H18N2O4

meprobamate

  • Molecular FormulaC9H18N2O4
  • Average mass218.250 Da
  • Monoisotopic mass218.126663 Da
  • ChemSpider ID3924

More details:



Featured data source



Validated by Experts, Validated by Users, Non-Validated, Removed by Users

1,3-Propanediol, 2-methyl-2-propyl-, dicarbamate [ACD/Index Name]
2-[(Carbamoyloxy)methyl]-2-methylpentyl carbamate [ACD/IUPAC Name]
2-[(carbamoyloxy)methyl]-2-methylpentyl carbamate (non-preferred name)
2-[(Carbamoyloxy)methyl]-2-methylpentylcarbamat [German] [ACD/IUPAC Name]
2-{[Hydroxy(imino)methoxy]methyl}-2-methylpentyl hydrogen carbonimidate [ACD/IUPAC Name]
2-{[Hydroxy(imino)methoxy]methyl}-2-methylpentylhydrogenkohlenstoffimidat [German] [ACD/IUPAC Name]
200-337-5 [EINECS]
200-659-6 [EINECS]
2-Methyl-2-propylpropane-1,3-diol dicarbamate
2-Metil-2-n-propil-1,3-propanediol dicarbamato [Spanish]
More...

Validated by Experts, Validated by Users, Non-Validated, Removed by Users

533 [DBID]
Bamd 400 [DBID]
Bamo 400 [DBID]
BRN 1788882 [DBID]
D00376 [DBID]
DEA No. 2820 [DBID]
HSDB 3117 [DBID]
M2392_SIGMA [DBID]
NCGC00091031-01 [DBID]
NSC30418 [DBID]
More...
  • Experimental Physico-chemical Properties
  • Miscellaneous
    • Appearance:

      white crystalline powder OU Chemical Safety Data (No longer updated) More details
    • Stability:

      Stable. Combustible. Incompatible with strong oxidizing agents. OU Chemical Safety Data (No longer updated) More details
    • Toxicity:

      IPR-HAM LD50 625 mg kg-1, ORL-HAM LD50 1410 mg kg-1, IPR-MUS LD50 331 mg kg-1, SCU-RAT LD50 525 mg kg-1 OU Chemical Safety Data (No longer updated) More details
    • Safety:

      N05BC01 Wikidata Q418351
      Safety glasses, adequate ventilation. OU Chemical Safety Data (No longer updated) More details
  • Gas Chromatography
    • Retention Index (Kovats):

      1652 (estimated with error: 89) NIST Spectra mainlib_250606, replib_335450, replib_10226, replib_221058, replib_246239, replib_312855
      1785 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 30 K/min; Start T: 100 C; End T: 310 C; End time: 5 min; Start time: 3 min; CAS no: 57534; Active phase: SE-30; Carrier gas: N2; Data type: Kovats RI; Authors: Maurer, H.H., Identification and differentiation of barbiturates, other sedative-hypnotics and their metabolites in urine integrated in a general screening procedure using computerized gas chromatography-mass spectrometry, J. Chromatogr., 530, 1990, 307-326.) NIST Spectra nist ri
      1758 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column diameter: 0.22 mm; Column length: 25 m; Column type: Capillary; Start T: 200 C; CAS no: 57534; Active phase: BP-1; Carrier gas: N2; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Japp, M.; Gill, R.; Osselton, M.D., Comparison of drug retention indices determined on packed, wide bore capillary and narrow bore capillary columns, J. Forensic Sci., 32(6), 1987, 1574-1586.) NIST Spectra nist ri
      1764 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column diameter: 0.53 mm; Column length: 25 m; Column type: Capillary; Start T: 200 C; CAS no: 57534; Active phase: BP-1; Carrier gas: N2; Phase thickness: 1 um; Data type: Kovats RI; Authors: Japp, M.; Gill, R.; Osselton, M.D., Comparison of drug retention indices determined on packed, wide bore capillary and narrow bore capillary columns, J. Forensic Sci., 32(6), 1987, 1574-1586.) NIST Spectra nist ri
      1752 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 300 C; End time: 12 min; Start time: 2 min; CAS no: 57534; Active phase: SE-30; Carrier gas: He; Phase thickness: 0.45 um; Data type: Kovats RI; Authors: Schepers, P.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A., Applicability of capillary gas chromatography to substance identification in toxicology by means of retention indices, J. Forensic Sci., 27(1), 1982, 49-60.) NIST Spectra nist ri
      1762 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.49 mm; Column length: 25 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 100 C; End T: 275 C; End time: 15 min; Start time: 2 min; CAS no: 57534; Active phase: SE-30; Phase thickness: 1.14 um; Data type: Kovats RI; Authors: Schepers, P.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A., Applicability of capillary gas chromatography to substance identification in toxicology by means of retention indices, J. Forensic Sci., 27(1), 1982, 49-60.) NIST Spectra nist ri
      1800 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 6 ft; Column type: Packed; CAS no: 57534; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb W; Data type: Kovats RI; Authors: McLinden, V.J.; Stenhouse, A.M., A chromatography system for drug identification, Forensic Sci. Int., 13, 1979, 71-79., Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column type: Packed; Start T: 200 C; CAS no: 57534; Active phase: OV-1; Data type: Kovats RI; Authors: Berninger, H.; Moller, M.R., Retentionsindices zur gaschromatographischen Identifizierung von Arzneimitteln, Arch. Toxicol., 37, 1977, 295-305.) NIST Spectra nist ri
      1790 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 2 m; Column type: Packed; CAS no: 57534; Active phase: SE-30; Data type: Kovats RI; Authors: Moffat, A.C.; Stead, A.H.; Smalldon, K.W., Optimum use of paper, thin-layer and gas-liquid chromatography for the identification of basic drugs. III. Gas-liquid chromatography, J. Chromatogr., 90, 1974, 19-33.) NIST Spectra nist ri
    • Retention Index (Lee):

      301.69 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Capillary; CAS no: 57534; Active phase: Methyl Silicone; Data type: Lee RI; Authors: Eckel, W.P.; Ross, B.; Isensee, R.K., Pentobarbital found in ground water, Ground Water, 31(5), 1993, 801-804.) NIST Spectra nist ri
      304.55 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Capillary; CAS no: 57534; Active phase: Methyl Silicone; Data type: Lee RI; Authors: Eckel, W.P.; Ross, B.; Isensee, R.K., Pentobarbital found in ground water, Ground Water, 31(5), 1993, 801-804.) NIST Spectra nist ri
    • Retention Index (Normal Alkane):

      1771 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.26 mm; Column length: 30 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 280 C; End time: 22 min; Start time: 1 min; CAS no: 57534; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Manca, D.; Ferron, L.; Weber, J-P., A System for Toxicological Screening by Capillary Gas Chromatography with Use of Drug Retention Index Based on Nitrogen-Containing Reference Compounds, Clin. Chem., 35(4), 1989, 601-607.) NIST Spectra nist ri
      1750 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.53 mm; Column length: 10 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 130 C; End T: 230 C; CAS no: 57534; Active phase: DB-1; Carrier gas: He; Phase thickness: 2.65 um; Data type: Normal alkane RI; Authors: Anderson, W.H.; Fuller, D.C., A simplified procedure for the isolation, characterization, and identification of weak acid and neutral drugs from whole blood, J. Anal. Toxicol., 11, 1987, 198-204.) NIST Spectra nist ri
      1758 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 130 C; End T: 290 C; End time: 10 min; Start time: 1 min; CAS no: 57534; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Sharp, M.E., A rapid screening procedure for acidic and neutral drugs in blood by high resolution gas chromatography, J. Anal. Toxicol., 11, 1987, 8-11.) NIST Spectra nist ri
      1810 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 2 m; Column type: Packed; Heat rate: 2.5 K/min; Start T: 120 C; End T: 200 C; CAS no: 57534; Active phase: OV-1; Substrate: Gas Chrom P; Data type: Normal alkane RI; Authors: Marozzi, E.; Gambaro, V.; Saligari, E.; Mariani, R.; Lodi, F., Use of the retention index in gas chromatographic studies of drugs, J. Anal. Toxicol., 6, 1982, 185-192., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 2 m; Column type: Packed; Heat rate: 2.5 K/min; Start T: 120 C; End T: 200 C; CAS no: 57534; Active phase: SE-30; Substrate: Gas Chrom P; Data type: Normal alkane RI; Authors: Marozzi, E.; Gambaro, V.; Saligari, E.; Mariani, R.; Lodi, F., Use of the retention index in gas chromatographic studies of drugs, J. Anal. Toxicol., 6, 1982, 185-192.) NIST Spectra nist ri
      1796 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Other; CAS no: 57534; Active phase: Methyl Silicone; Data type: Normal alkane RI; Authors: Ardrey, R.E.; Moffat, A.C., Gas-liquid chromatographic retention indices of 1318 substances of toxicological interest on SE-30 or OV-1 stationary phase, J. Chromatogr., 220, 1981, 195-252.) NIST Spectra nist ri
      1785 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 6 ft; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 57534; Active phase: SE-30; Carrier gas: N2; Substrate: Chromosorb W AW DMS; Data type: Normal alkane RI; Authors: Peel, H.W.; Perrigo, B., A practical gas chromatographic screening procedure for toxicological analysis, Can.Soc.Forens.Sci.J., 9(2), 1975, 69-74., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 6 ft; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 57534; Active phase: SE-30; Carrier gas: Nitrogen; Substrate: Chromosorb W AW DMS (80-100 mesh); Data type: Normal alkane RI; Authors: Peel, H.W.; Perrigo, B., A practical gas chromatographic screening procedure for toxicological analysis, Can. Soc. Forens. Sci. J., 9(2), 1976, 69-74.) NIST Spectra nist ri
      1830 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 6 ft; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 57534; Active phase: SE-30; Carrier gas: N2; Substrate: Chromosorb W AW DMS; Data type: Normal alkane RI; Authors: Peel, H.W.; Perrigo, B., A practical gas chromatographic screening procedure for toxicological analysis, Can.Soc.Forens.Sci.J., 9(2), 1975, 69-74., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 6 ft; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 57534; Active phase: SE-30; Carrier gas: Nitrogen; Substrate: Chromosorb W AW DMS (80-100 mesh); Data type: Normal alkane RI; Authors: Peel, H.W.; Perrigo, B., A practical gas chromatographic screening procedure for toxicological analysis, Can. Soc. Forens. Sci. J., 9(2), 1976, 69-74.) NIST Spectra nist ri
      1826 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.20 mm; Column length: 25 m; Column type: Capillary; Description: 50 0C (0.5 min) ^ 99 0C/min -> 100 0C (1 min) ^ 15 0C/min -> 280 0C (20 min); CAS no: 57534; Active phase: 5 % Phenyl methyl siloxane; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Grigoriev, A.M.; Savchuk, S.A., Correlation of the parameters of screening libraries of the gas-chromatographic retention data, Rus. J. Anal. Chem. (Engl. Transl.), 65(4), 2010, 388-397, In original 400-409.) NIST Spectra nist ri
      1832 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.20 mm; Column length: 25 m; Column type: Capillary; Description: 50 0C (0.5 min) ^ 99 0C/min -> 100 0C (1 min) ^ 15 0C/min -> 280 0C (20 min); CAS no: 57534; Active phase: 5 % Phenyl methyl siloxane; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Grigoriev, A.M.; Savchuk, S.A., Correlation of the parameters of screening libraries of the gas-chromatographic retention data, Rus. J. Anal. Chem. (Engl. Transl.), 65(4), 2010, 388-397, In original 400-409.) NIST Spectra nist ri
      1802.5 (Program type: Ramp; Column cl... (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 12.5 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 110 C; End T: 290 C; End time: 6.5 min; Start time: 1 min; CAS no: 57534; Active phase: Ultra-2; Phase thickness: 0.5 um; Data type: Normal alkane RI; Authors: Watts, V.W.; Simonick, T.F., A retention index library for commonly encountered drugs and metabolites using tri-n-alkylamines as reference compounds, nitrogen-phosphorus detectors, and dual capillary chromatography, J. Anal. Toxicol., 11, 1987, 210-214.) NIST Spectra nist ri
    • Retention Index (Linear):

      1784 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.75 mm; Column length: 30 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 160 C; End T: 280 C; End time: 12 min; CAS no: 57534; Active phase: SPB-1; Carrier gas: He; Phase thickness: 1.0 um; Data type: Linear RI; Authors: Christ, D.W.; Noomano, P.; Rosas, M.; Rhone, D., Retention indices by wide-bore capillary gas chromatography with nitrogen-phosphorus detection, J. Anal. Toxicol., 12, 1988, 84-88.) NIST Spectra nist ri
      1762 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 280 C; End time: 5 min; CAS no: 57534; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Perrigo, B.J.; Ballantyne, D.J.; Peel, H.W., Condierations in developing a data base for drugs on a DBI capillary column, J. Can. Soc. Forensic Sci., 17(2), 1984, 41-49., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 15 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 280 C; End time: 5 min; CAS no: 57534; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Perrigo, B.J.; Peel, H.W.; Ballantyne, D.J., Use of Dual-Column Fused-Silica Capillary Gas Chromatography in Combination with Detector Response Factors for Analytical Toxicology., J. Chromatogr., 341, 1985, 81-88.) NIST Spectra nist ri
      1758 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.2 mm; Column length: 12 m; Column type: Capillary; Heat rate: 20 K/min; Start T: 50 C; End T: 300 C; End time: 3 min; Start time: 1 min; CAS no: 57534; Active phase: Methyl Silicone; Carrier gas: He; Phase thickness: 0.33 um; Data type: Linear RI; Authors: Newton, B.; Foery, R.F., Retention indices and dual capillary gas chromatography for rapid identification of sedative hypnotic drugs in emergency toxicology, J. Anal. Toxicol., 8, 1984, 129-134.) NIST Spectra nist ri
      1780 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 1.8 m; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 57534; Active phase: SE-30; Carrier gas: N2; Substrate: Chromosorb W; Data type: Linear RI; Authors: Perrigo, B.J.; Peel, H.W., The use of retention indices and temperature-programmed gas chromatography in analytical toxicology, J. Chromatogr. Sci., 19, 1981, 219-226.) NIST Spectra nist ri

Predicted data is generated using the ACD/Labs Percepta Platform - PhysChem Module, version: 14.00

Density: 1.2±0.1 g/cm3
Boiling Point: 333.6±52.0 °C at 760 mmHg
Vapour Pressure: 0.0±1.6 mmHg at 25°C
Enthalpy of Vaporization: 66.8±6.0 kJ/mol
Flash Point: 155.5±30.7 °C
Index of Refraction: 1.488
Molar Refractivity: 52.5±0.5 cm3
#H bond acceptors: 6
#H bond donors: 4
#Freely Rotating Bonds: 8
#Rule of 5 Violations: 0
ACD/LogP: 1.14
ACD/LogD (pH 5.5): -1.82
ACD/BCF (pH 5.5): 1.00
ACD/KOC (pH 5.5): 1.00
ACD/LogD (pH 7.4): -1.82
ACD/BCF (pH 7.4): 1.00
ACD/KOC (pH 7.4): 1.00
Polar Surface Area: 107 Å2
Polarizability: 20.8±0.5 10-24cm3
Surface Tension: 42.6±7.0 dyne/cm
Molar Volume: 182.3±7.0 cm3

Predicted data is generated using the US Environmental Protection Agency�s EPISuite™

                        
 Log Octanol-Water Partition Coef (SRC):
    Log Kow (KOWWIN v1.67 estimate) =  0.98
    Log Kow (Exper. database match) =  0.70
       Exper. Ref:  Hansch,C et al. (1995)

 Boiling Pt, Melting Pt, Vapor Pressure Estimations (MPBPWIN v1.42):
    Boiling Pt (deg C):  282.95  (Adapted Stein & Brown method)
    Melting Pt (deg C):  46.59  (Mean or Weighted MP)
    VP(mm Hg,25 deg C):  0.000792  (Modified Grain method)
    MP  (exp database):  105 deg C
    Subcooled liquid VP: 0.0048 mm Hg (25 deg C, Mod-Grain method)

 Water Solubility Estimate from Log Kow (WSKOW v1.41):
    Water Solubility at 25 deg C (mg/L):  8877
       log Kow used: 0.70 (expkow database)
       no-melting pt equation used
     Water Sol (Exper. database match) =  4700 mg/L (25 deg C)
        Exper. Ref:  YALKOWSKY,SH & DANNENFELSER,RM (1992)

 Water Sol Estimate from Fragments:
    Wat Sol (v1.01 est) =  9764.7 mg/L
    Wat Sol (Exper. database match) =  4700.00
       Exper. Ref:  YALKOWSKY,SH & DANNENFELSER,RM (1992)

 ECOSAR Class Program (ECOSAR v0.99h):
    Class(es) found:
       Esters

 Henrys Law Constant (25 deg C) [HENRYWIN v3.10]:
   Bond Method :   1.85E-010  atm-m3/mole
   Group Method:   Incomplete
 Henrys LC [VP/WSol estimate using EPI values]:  2.562E-008 atm-m3/mole

 Log Octanol-Air Partition Coefficient (25 deg C) [KOAWIN v1.10]:
  Log Kow used:  0.70  (exp database)
  Log Kaw used:  -8.121  (HenryWin est)
      Log Koa (KOAWIN v1.10 estimate):  8.821
      Log Koa (experimental database):  None

 Probability of Rapid Biodegradation (BIOWIN v4.10):
   Biowin1 (Linear Model)         :   0.6188
   Biowin2 (Non-Linear Model)     :   0.5511
 Expert Survey Biodegradation Results:
   Biowin3 (Ultimate Survey Model):   2.4113  (weeks-months)
   Biowin4 (Primary Survey Model) :   3.7667  (days        )
 MITI Biodegradation Probability:
   Biowin5 (MITI Linear Model)    :   0.2420
   Biowin6 (MITI Non-Linear Model):   0.3140
 Anaerobic Biodegradation Probability:
   Biowin7 (Anaerobic Linear Model):  0.4467
 Ready Biodegradability Prediction:   NO

Hydrocarbon Biodegradation (BioHCwin v1.01):
    Structure incompatible with current estimation method!

 Sorption to aerosols (25 Dec C)[AEROWIN v1.00]:
  Vapor pressure (liquid/subcooled):  0.64 Pa (0.0048 mm Hg)
  Log Koa (Koawin est  ): 8.821
   Kp (particle/gas partition coef. (m3/ug)):
       Mackay model           :  4.69E-006 
       Octanol/air (Koa) model:  0.000163 
   Fraction sorbed to airborne particulates (phi):
       Junge-Pankow model     :  0.000169 
       Mackay model           :  0.000375 
       Octanol/air (Koa) model:  0.0128 

 Atmospheric Oxidation (25 deg C) [AopWin v1.92]:
   Hydroxyl Radicals Reaction:
      OVERALL OH Rate Constant =  19.3251 E-12 cm3/molecule-sec
      Half-Life =     0.553 Days (12-hr day; 1.5E6 OH/cm3)
      Half-Life =     6.642 Hrs
   Ozone Reaction:
      No Ozone Reaction Estimation
   Fraction sorbed to airborne particulates (phi): 0.000272 (Junge,Mackay)
    Note: the sorbed fraction may be resistant to atmospheric oxidation

 Soil Adsorption Coefficient (PCKOCWIN v1.66):
      Koc    :  173.4
      Log Koc:  2.239 

 Aqueous Base/Acid-Catalyzed Hydrolysis (25 deg C) [HYDROWIN v1.67]:
  Total Kb for pH > 8 at 25 deg C :  1.320E-004  L/mol-sec
  Kb Half-Life at pH 8:     166.327  years  
  Kb Half-Life at pH 7:    1663.267  years  

 Bioaccumulation Estimates from Log Kow (BCFWIN v2.17):
   Log BCF from regression-based method = 0.500 (BCF = 3.162)
       log Kow used: 0.70 (expkow database)

 Volatilization from Water:
    Henry LC:  1.85E-010 atm-m3/mole  (estimated by Bond SAR Method)
    Half-Life from Model River: 4.675E+006  hours   (1.948E+005 days)
    Half-Life from Model Lake :   5.1E+007  hours   (2.125E+006 days)

 Removal In Wastewater Treatment:
    Total removal:               1.87  percent
    Total biodegradation:        0.09  percent
    Total sludge adsorption:     1.77  percent
    Total to Air:                0.00  percent
      (using 10000 hr Bio P,A,S)

 Level III Fugacity Model:
           Mass Amount    Half-Life    Emissions
            (percent)        (hr)       (kg/hr)
   Air       0.00248         13.3         1000       
   Water     43.3            900          1000       
   Soil      56.6            1.8e+003     1000       
   Sediment  0.0873          8.1e+003     0          
     Persistence Time: 1.01e+003 hr




                    

Click to predict properties on the Chemicalize site






Advertisement